BURNER
Ø BYPASS 1/100 mm
Rapid
55
Multi Crown
67
Oven
54
Grill
59
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Multi Crown
4.0
1.8
146
Rapid
3.0
1.1
119o
Semi-rapid
2.0
0.45
96
Auxiliary
1.0
0.35
70
Oven
3.6
1.5
126
Grill
2.5
1.6
111
14.6 Gas burners for LPG G30 28-30 mbar
BURNER
NORMAL
POWER kW
GAS RATE g/h
REDUCED
POWER kW
INJECTOR MARK
1/100 mm
Multi Crown
3.2
232.7
1.8
90x
Rapid
2.9
210.9
1.1
83
Semi-rapid
2.0
145.4
0.43
71
Auxiliary
1.0
72.7
0.35
50
Oven
3.6
261.8
1.5
90
Grill
2.5
181.8
1.6
80
14.7 Gas connection
WARNING!
Before you connect the gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the
fuse box. Close the primary
valve of the gas supply.
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
ENGLISH