background image

 

3 Programme 

table 

 

Programmes

 

Prewash

 

Was

 

Rinse Extra 

rinse

 

Hot rinse

 

 

Program

me na

me 

Programme button to be 

pressed 

Heating (ºC) 

Wash ti

me after 

heati

ng (mi

n.) 

Ty

pe

 of wa

sh

 

Heating (ºC) 

Wash ti

me after 

heati

ng (mi

n.) 

Heating (ºC) 

Wash ti

me after 

heati

ng (mi

n.) 

Ty

pe

 of wa

sh

 

Wash ti

me (min.) 

Wash ti

me (minutes

Ty

pe

 of wa

sh

 

Wash ti

me 

Wash ti

me after 

heati

ng (mi

n.) 

Ty

pe

 of wa

sh

 

Heating (ºC) 

Wash ti

me after 

heati

ng (mi

n.) 

Program

me ti

m

(mi

n.) 

Intensive 

(

T) 

55°C 

T+10'

ctrl 

(

T) 

55°C 

T+5'

(

T) 

68°C 

+14'

ctrl 

2x3’ 

(<65°C) 

2x 

T+3’

ctrl 

5’ 

(<60°C)

--- PW1 (

T) 69°C

--- 

105’ 

ECO 

--- 

T+10' PW4 11’(<62°)

T+47'

--- --- 

PW4 

5’(<60°C)

--- 

PW1

--- 

T+4’ PW4 

10’ 

(<69°C) 

--- 160‘ 

Automatic 

--- 

T+8' ctrl 

(

T) 

50°C 

T+4'

(

T) 

68°C 

T+8' ctrl --- 

T+4’ PW1

5’ 

(<60°C)

--- PW1 (

T) 69°C

T+1’

30‘-

100’ 

Soak 

--- 

T+8' 

PW1

---  ---  --- --- 

---  ---  --- --- --- --- --- 

--- 

--- 12‘ 

 
 
Notes

: The total time of the programmes is indicative since it depends both on the water pressure and temperature and on the voltage variations.

 

Summary of Contents for EDW 2000 DIVA

Page 1: ...CTS ITALY S p A Spares Operations Italy Corso Lino Zanussi 30 Publication no I 33080 PORCIA PN ITALY 599 36 92 49 Fax 39 0434 394096 Edition 2005 12 EN Dishwasher with electronic control EDW 2000 Functions DIVA 60 cm V I S I Production ZM Solaro IT ...

Page 2: ...cle stops Drain circuit obstructed blocked drain pump interrupted or jammed foreign bodies level pressure switch blocked on FULL 1 3 hydraulic circuit of pressure switch obstructed wiring faulty circuit board faulty i30 3 yes Intervention of Anti flooding system the drain pump switches on The cycle is interrupted and the drain pump switches on Water leakage from the tub sump and various connection...

Page 3: ...e washing pump operates at maximum speed and the alarm code is stored in memory the cycle continues Motor winding interrupted short circuited motor jammed foreign bodies wiring to washing motor faulty motor capacitor faulty Tachometric generator interrupted short circuited circuit board faulty iF0 15 no Water replenishment Time out 3 times during the T S Time out The cycle continues until the next...

Page 4: ...2 ELECTRICAL FUNCTIONS 2 1 Electrical circuit diagram ...

Page 5: ...spenser EC Fill solenoid ER Regeneration solenoid GA Suppressor IP Door switch MR General terminal block MV Fan motor PL Washing pump PS Drain pump PU Pushbutton array PR RL Level pressure switch PA Anti overflow pressure switch RR Heating element SB Rinse aid sensor SS Salt sensor Turbidity Turbidity sensor ST Temperature sensor TAC T Tachometric generator TS Safety thermostat Main Board Main boa...

Page 6: ...LUES NOTES L B1 0 Ω POWER CABLE PU ON OFF SWITCH N A2 0 Ω with ON OFF button held down RR HEATING ELEMENT TS SAFETY THERMOSTAT A1 C5 25 Ω 8 connected in series 2100W INFINITE on EMPTY 1 2 PR LEVEL PRESSURE SWITCH B1 C5 0 Ω on FULL 1 3 INFINITE on EMPTY 1 2 PA ANTI FLOODING PRESSURE SWITCH C1 A2 0 Ω on FULL 1 3 IP DOOR MICROSWITCH B2 D1 0 Ω Door closed DD DB INTEGRATED DISPENSER D5 D7 1 500 Ω 8 OK ...

Page 7: ...ash time Wash time after heating min Type of wash Heating ºC Wash time after heating min Programme time min Intensive T 55 C T 10 ctrl T 55 C T 5 T 68 C T 14 ctrl 2x3 65 C 2x T 3 ctrl 5 60 C PW1 T 69 C 105 ECO T 10 PW4 11 62 T 47 PW4 5 60 C PW1 T 4 PW4 10 69 C 160 Automatic T 8 ctrl T 50 C T 4 T 68 C T 8 ctrl T 4 PW1 5 60 C PW1 T 69 C T 1 30 100 Soak T 8 PW1 12 Notes The total time of the programm...

Page 8: ...nents are activated i 0 i 0 i 0 4 5 6 7 8 9 10 AL 1 AL2 AL 3 ER PS EV RR PL DD MV Cancellation of alarms in memory S1 S3 S0 On Off LD1 LD2 LD3 flashing S2 All LEDs and the lamp inside the tub flash All LEDs flash for 30 sec Test cycle S1 S3 S0 On Off LD1 LD2 LD3 flashing S3 LD3 flashes Automatic LED flashes The cycle starts automatically Extra rinse S1 S3 S0 On Off LD1 LD2 LD3 flashing S1 S2 S1 LD...

Reviews: