background image

 

 

Type of 

Alarm 

No. flashes 

of end-of-

cycle LED 

Displayed 

to the 

user 

Description of the alarm condition 

Machine status 

Possible causes 

i70 

no 

NTC sensor short-circuited or open 

The programme continues to the 

end without heating (the washing 

result will probably be 

unsatisfactory) 

NTC sensor faulty; wiring short-circuited / open; 
circuit board faulty. 

i80 

no 

Communication error between the 

microprocessor and the EEPROM 

Machine inoperative: no selection 

possible 

(*)

 

Circuit board faulty. 

i90 

no 

Problems with software configuration 

The fault occurs when switching 

on: no selection possible 

(*)

 

Circuit board faulty 

(configuration software incorrect). 

ib0 

11 

no 

Problems with the turbidity meter

 

[if featured] (Calibration Time-out) 

The programme continues as if a 

“heavy soiling” condition had been 

detected. 

Turbidity sensor faulty; sensor wiring faulty; circuit 

board faulty. 

id0 

13 

no 

Problems with the washing motor: no 

signal from the tachometric generator

 

(washing pump powered, but no signal 

from the generator) 

The heating element is switched 

off. If the fault persists after the 

Time-out, the washing pump 

operates at maximum speed and 

the alarm code is stored in 

memory (the cycle continues) 

Motor winding interrupted / short-circuited; motor 

jammed (foreign bodies); wiring to washing motor 

faulty; motor capacitor faulty; Tachometric 

generator interrupted / short-circuited; circuit board 

faulty. 

iF0 

15 

no 

Water replenishment Time-out 

(3 times during the T.S. Time-out) 

The cycle continues until the next 
phase without supplementary fills 

and without heating. The error is 

cancelled on completion of a drain 

phase. 

Dishes upside-down; central filter clogged; 

excessive foam; leaks from the sump-pressure 

switch coupling; pressure switch faulty / false 

contacts; wrong positioning of the drain hose  

i  0 

no 

No alarm memorised. 

 
 
 (*)

  If it is not possible to access diagnostics mode, switch the appliance off and then on again to check that this is not caused by a temporary fault. Before replacing the    

circuit board, check that it is correctly powered by controlling: 

  Continuity of the power cable,  Correct operation of the suppressor, Closure of the door switch contacts, Continuity of the wiring between connectors A2 / B1 on the 

circuit board and the suppressor. 

(**) The alarm conditions with the flashing of the current programme and the switching on of the ON/OFF LED in red are displayed to the user.

Summary of Contents for EDW 2000 DIVA

Page 1: ...CTS ITALY S p A Spares Operations Italy Corso Lino Zanussi 30 Publication no I 33080 PORCIA PN ITALY 599 36 92 49 Fax 39 0434 394096 Edition 2005 12 EN Dishwasher with electronic control EDW 2000 Functions DIVA 60 cm V I S I Production ZM Solaro IT ...

Page 2: ...cle stops Drain circuit obstructed blocked drain pump interrupted or jammed foreign bodies level pressure switch blocked on FULL 1 3 hydraulic circuit of pressure switch obstructed wiring faulty circuit board faulty i30 3 yes Intervention of Anti flooding system the drain pump switches on The cycle is interrupted and the drain pump switches on Water leakage from the tub sump and various connection...

Page 3: ...e washing pump operates at maximum speed and the alarm code is stored in memory the cycle continues Motor winding interrupted short circuited motor jammed foreign bodies wiring to washing motor faulty motor capacitor faulty Tachometric generator interrupted short circuited circuit board faulty iF0 15 no Water replenishment Time out 3 times during the T S Time out The cycle continues until the next...

Page 4: ...2 ELECTRICAL FUNCTIONS 2 1 Electrical circuit diagram ...

Page 5: ...spenser EC Fill solenoid ER Regeneration solenoid GA Suppressor IP Door switch MR General terminal block MV Fan motor PL Washing pump PS Drain pump PU Pushbutton array PR RL Level pressure switch PA Anti overflow pressure switch RR Heating element SB Rinse aid sensor SS Salt sensor Turbidity Turbidity sensor ST Temperature sensor TAC T Tachometric generator TS Safety thermostat Main Board Main boa...

Page 6: ...LUES NOTES L B1 0 Ω POWER CABLE PU ON OFF SWITCH N A2 0 Ω with ON OFF button held down RR HEATING ELEMENT TS SAFETY THERMOSTAT A1 C5 25 Ω 8 connected in series 2100W INFINITE on EMPTY 1 2 PR LEVEL PRESSURE SWITCH B1 C5 0 Ω on FULL 1 3 INFINITE on EMPTY 1 2 PA ANTI FLOODING PRESSURE SWITCH C1 A2 0 Ω on FULL 1 3 IP DOOR MICROSWITCH B2 D1 0 Ω Door closed DD DB INTEGRATED DISPENSER D5 D7 1 500 Ω 8 OK ...

Page 7: ...ash time Wash time after heating min Type of wash Heating ºC Wash time after heating min Programme time min Intensive T 55 C T 10 ctrl T 55 C T 5 T 68 C T 14 ctrl 2x3 65 C 2x T 3 ctrl 5 60 C PW1 T 69 C 105 ECO T 10 PW4 11 62 T 47 PW4 5 60 C PW1 T 4 PW4 10 69 C 160 Automatic T 8 ctrl T 50 C T 4 T 68 C T 8 ctrl T 4 PW1 5 60 C PW1 T 69 C T 1 30 100 Soak T 8 PW1 12 Notes The total time of the programm...

Page 8: ...nents are activated i 0 i 0 i 0 4 5 6 7 8 9 10 AL 1 AL2 AL 3 ER PS EV RR PL DD MV Cancellation of alarms in memory S1 S3 S0 On Off LD1 LD2 LD3 flashing S2 All LEDs and the lamp inside the tub flash All LEDs flash for 30 sec Test cycle S1 S3 S0 On Off LD1 LD2 LD3 flashing S3 LD3 flashes Automatic LED flashes The cycle starts automatically Extra rinse S1 S3 S0 On Off LD1 LD2 LD3 flashing S1 S2 S1 LD...