4 QUICK GUIDE TO SPECIAL FUNCTIONS
The table below contains a brief description of the functions available to the user and to service personnel.
(*)
No “user” functions are available if a cycle has been selected (the appliance must be in the pre-selection mode).
Function
Method of selection
Method of activation
Short description / Comments
Buttons
LED(s)
Buttons
LED(s)
Regeneration
level
S0
(On/Off)
[
S1
+
S2
]
LD1
+
LD2
+
LD3
flashing
S1
LD1 flashes
“Automatic” LED
flashes to
indicate the level
When button S1 is pressed repeatedly :
Lev….[
1L
]……[
2L
]….[
3L
]…...[
4L
]……[
5L
]…. [ 6L
]…...[
7L
] .…[
8L
]……[ 9L]….…[10L]
°F… >8 ….. >14 ..…>20 ….. >30 ….. >40 ….. >50 ….. >60 ….. >70 ….. >80 ….... >90
°D… >4 …... >8 ..…. >11 ..... >17 ….. >22 ….. >28 ….. >33 ….. >39 ….. >45 ……. >50
USER (*)
Reset
S0
(On/Off)
[
S1
+
S2
]
All LEDs switch
off
Display of alarms
and components
diagnostic
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
S1
LD1 flashes
“Automatic” LED
flashes to
indicate the alarm
When button
S1 is pressed 4 times
, the L3 LED flashes centrally to indicate
that the components are activated
:
[i.0] [i.0] [i.0] [
4
] [
5
] [
6
] [ 7
] [
8
] [ 9
] [10]
AL 1 AL2 AL 3
ER
PS
EV RR PL DD MV
Cancellation of
alarms in
memory
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
S2
All LEDs and the
lamp inside the
tub flash
All LEDs flash for 30 sec.
Test cycle
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
S3
LD3 flashes
“Automatic” LED
flashes
The cycle starts automatically.
Extra rinse
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
[
S1
+
S2
]
S1
LD1 flashes
The “Automatic”
LED indicates if
the function is
active or not
Pressing button S1 toggles function:
LED on = rinse enabled; LED off = disabled
SERVICE
Disabling of
pulse washing
[
S1
+
S3
]
S0
(On/Off)
LD1
+
LD2
+
LD3
flashing
[
S2
+
S3
]
S3
LD3 flashes
The “Automatic”
LED indicates if
the function is
active
Pressing button S3 toggles function:
LED on = Pulse washing PW enabled; LED off = Continuous washing
Exit / storage in
memory
To store programmed functions or exit from the diagnostic mode, turn off the unit using the
S0
(
On/Off) button. In most cases, the programming is stored or the
diagnostic mode is exited automatically after 60 seconds (in this case, the machine sets itself to the pre-selection mode).