- 9 -
03.2004 R.K.
599 519 400
EN
4.2 Drain Pump
The drain pump is driven by a synchronous motor.
Power output 26 W.
Pump rate 15 l/min.
Flap trap
4.3 Flow Heater
The flow heater heats the water to the required temperature. During the
wash cycle, water is contantly passing through the flow heater.
Power output
2100 W
Resistor
25
W
Protector
98 °C ± 5 K
Thermal fuse
260 °C
4. Components
4.1 Circulation Pump
The circulation pump is driven by an asynchronous motor with an
auxiliary winding. The auxiliary winding ist in circuit with a 3 mF
capacitor. A tacho generator is used for speed control.
There are three speeds for rinsing.
1600 1/min,to 2800 1/min, Power output 50 W.
Coil resistances
Main winding
38 Ohm
aux. winding
110 Ohm
Tacho
ca. 220 Ohm
4.4 Pressure Switch
The pressure switch controls the water level.
Without water, contact 11 - 12 is closed.
Niv 1 = Switch point 75 mmWS / Reset point 30 mmWS
Niv 2 = Switch point 97 mmWS / Reset point 70 mmWS
75 / 97 mm