14 www.electroluxaircomfort.com
NOTE
• Make sure that the live wire, the neutral wire
and the ground wire in the mains socket are
properly connected.
• Inadequate or incorrect electrical
connections can cause electric shock or fi re.
Grounding requirements
• The unit is a type I electrical appliance. Make
sure that the unit is properly grounded.
• The yellow-green wire is the ground wire
that cannot be used for other purposes.
Improper grounding can cause electric
shock.
• The ground resistance must comply with
local regulations.
• The mains supply must have reliable ground
terminal. Do not connect the ground wire to
water pipes, gas pipes, contamination pipes
or other possible unsafe places.
• Fuses must comply with the prescribed
model and rating printed on the fuse cover or
circuit board.
INSTALLATION DRAWING
The dimensions required for proper installation
of the unit include the minimum permissible dis-
tances to adjacent parts.
* Recommended distance for maximum airfl ow is 15 cm.