circuit because the circuit operating
temperature is high.
• The pipes connecting the indoor and
outdoor unit are not included in the unit.
• The outdoor unit is powered by the indoor
unit.
Installation site
Do not install the unit in areas with:
• strong heat sources;- vapours or fl ammable
gasses;
• contamination with oil particles;
• high frequency electromagnetic equipment
(e.g. welding equipment or medical devices);
• high salinity (e.g. close to coastal areas);
• sulphuric gas (e.g hot water springs);
• poor air quality.
Indoor unit
• Maintain the minimum installation distances
specifi ed in this document. Do not block the
air inlet or the air outlet.
• Do not use the unit in places with extremely
high humidity.
• Install the indoor unit out of reach of children
• The wall must be strong enough to support
the weight and vibration of the unit.
• Install the indoor unit at least 50 cm above
the fl oor surface.
• Leave suffi cient space for cleaning and
maintenance.
• The air fi lter should remain accessible.
• Leave at least 1 m distance between the unit
and other electrical appliances.
• Install the indoor unit in a place where the
condensate water can be easily drained
• Install at a location protected from direct
sunlight.
Outdoor unit
• Maintain the minimum installation distances
specifi ed in this document.
• Do not block the air inlet or the air outlet
• Install the outdoor unit out of reach of
children.
• Install the outdoor unit where there is
suffi cient ventilation.
• Install the outdoor unit where produced
noise and airfl ow will not disturb neighbours
or animals.
• Install the outdoor unit in a dry place.
• Install the outdoor unit in a place not
exposed to direct sunlight or strong wind.
• Install the unit in a place that supports the
weight and vibration of the unit.
• The height difference between the indoor unit
and the outdoor unit must be less than 5 m.
• The length of the connecting pipes must be
less than 10 m.
• Leave suffi cient space for cleaning and
maintenance.
• The outdoor unit is powered by the indoor
unit.
Safety precautions for electrical appliances
• Use a dedicated mains circuit.
• The unit must be properly grounded.
• Install a Residual-current device (RCD) to
protect against personal injury in case of
leakage currents.
• Use an all pole disconnection switch with
a contact separation of at least 3 mm in
all poles in fi xed wiring. For models with a
mains plug, make sure that the mains plug is
within reach after installation.
• The installation must comply with local
electrical safety regulations and with other
relevant local regulations
• The unit must be installed in accordance with
national wiring regulations.
• Do not subject the mains cable to force.
• The distance between the unit and heat
sources is at least 1.5 m.
• Use an air switch. The air switch must have
functions for magnetic tripping and heat
tripping to prevent short circuit and overload.
The suitable capacity is specifi ed in the
following table.
Air conditioner (Btu)
Air switch capacity
09-12K
16A