62
Anom-
aly
Type of
anomaly
Description
Possible causes
Actions
FSnr
Warning
Cooling fan issue
• Inlet air filter dirty
• Cooling fan failure
• Clean inlet air filter;
• Check with a thin strip of paper whether a
consistent air flow can be detected at the
cooling air inlet: if not, call Service.
FUXX
(XX = 00
- 17)
Stops oven
Upper cavity motor
failure
Diagnostic according to
error number (from 00 to 17)
displayed.
Switch the oven OFF/ON;
If the error persists, manually clean the oven
cavity and call Service.
GbbU
Stops the
boiler
Boiler gas burner
locked
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
The oven can continue to work both in convec-
tion and ISG mode.
To recover full boiler functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open
2. reset the error and attempt new cycle
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
GbCd
Cycle
paused
Cavity lower burner
locked
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
The oven will not operate until restoring the
burner functionality.
To recover the functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open
2. reset the error and attempt new cycle
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
GbCU
Cycle
paused
Cavity upper burner
locked
• Air in gas supply;
• Gas supply is closed;
• Issue with the electric
supply of the burner
system;
• Burner system internal
failure;
The oven will not operate until restoring the
burner functionality.
To recover the functionality:
• Switch the oven OFF/ON.
• If the error occurs at the cycle start, call
Service.
• If the error occurs after 5 ignition attempts:
1. check the gas supply main valve is open
2. reset the error and attempt new cycle
3. if the error persists, switch OFF/ON the
oven and attempt new cycle again;
4. if the error persists, call Service
GrCo
Stops
cleaning
cycle
Grease collector valve
opened
Misuse
Ensure to close the grease collector drain valve
before restarting the cleaning cycle.
HdXX
(XX =
01-26)
Stops oven
Valves/pumps
activations
Diagnostic according to
error number (from 01 to 26)
displayed.
Switch the oven OFF/ON;
If the error persists, follow instructions displayed.
If the error persists, manually clean the oven
cavity and call Service.
HFnI
Warning
Humidifier not working
• Water missing;
• ISG circuit obstruction.
The oven has detected a problem with the
humidifier.
Verify the water supply valve is fully open and
the water filler has no obstructions. Clean it if
needed.