DGS-TDS-N 05.09 A. B. © Electrolux
599 518 252
EN
5.3
Measure against wrong electrical connection
Not provided.
5.
Technical equipment
5.1
Temperature safety device
With built-in appliances, there is a temperature fuse on the side of the air channel that switches off
the appliance in the event of overheating. The measured temperature value during a cutoff is 90°C.
Fig.: Built-in position - Temperature fuse
Notes:
-
for wiring diagram see chapter 7
-
Deviations possible with floor-mounted stoves
5.2
Fan after-running
The cooling fan switches on automatically when putting the appliance into operation. First it is in
operation to keep cool the appliance surfaces. After the oven was switched off, the fan continues
running to cool the appliance and then switches off automatically at a centre of gravity temperature
of the muffle of approx. 120°C-130°C. The post-operative ventilation is controlled via the
electronics.
Note:
-
for wiring diagram see chapter 7
-
Deviations possible with floor-mounted stoves
Summary of Contents for Built-in appliances
Page 37: ... 37 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 2 Example circuit diagram OVC 1000 ...
Page 38: ... 38 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 3 Example circuit diagram OVC 2000 ...
Page 39: ... 39 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 4 Example circuit diagram SOEC ...
Page 40: ... 40 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 5 Example circuit diagram Prisma ...
Page 41: ... 41 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 6 Example circuit diagram HOC 2000 ...
Page 42: ... 42 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 7 Operative Equipment Overview ...
Page 43: ... 43 DGS TDS N 05 09 A B Electrolux 599 518 252 EN Changes Pages 34 Chapter 6 1 changed ...