- 34 -
DGS-TDS-N 05.09 A. B. © Electrolux
599 518 252
EN
6.
Fault diagnosis/ What to do if ...?
6.1
Alarmmanagement (Faultcodes)
Alarmmanagement Power Electronic SOEC
Display
Description of Fault
Possible Fault
E 001
Too high temperature in the
muffle in pyrolysis operation
(door locked)
Relay stuck, fault in the
control, sensor not measuring
correctly
E 008
Short circuit at the sensor
entrance
Sensor defective, wiring
defective
E 020
Too high temperature at the
muffle in normal operation
(door not locked)
Pyrolysis type of operation:
Fault during locking or locking
feedback during pyrolysis
Non-pyrolysis type of
operation:
Too high temperature at the
muffle, relay stuck, fault in the
control, sensor not measuring
correctly
E 021
Initially too high temperature
during pyrolysis (door locked)
then door unlocked
Relay stuck, fault in the
control, sensor not measuring
correctly
E 025
Sensor not connected
Sensor defective, wiring
defective, sensor circuit open
E 080
Heaters are switched on, but
no rise in temperature takes
place within approx. 7 min.
Only active below approx. 70
°C
Heaters are not connected
(slow-break switching), heater
defective, sensor not at the
muffle
Display
Description of fault
Fault repair
F0
Internal error
replace power electronics
F1
door cannot be locked
Test door locking system
F2
door cannot be unlocked
Test door locking system and unlocking thermostat
f11
F3
software error
Execute network reset by disconnecting the
appliance from the electricity supply and restarting
F94
Temperature sensor alarm - resulting in F4
Test temperature sensor, replace if necessary
F4
Temperature sensor without contact or short circuit Test temperature sensor, replace if necessary
F5
Clotted heating element relay contacts on the
power electronics
Replace power electronics
F95
Temperature alarm at power electronics - resulting
in F6
Test built-in situation of the ventilation channel and
the function of the cooling fan
F96
Temperature alarm at power electronics - resulting
in F6
Test built-in situation of the ventilation channel and
the function of the cooling fan
F6
Power electronics temperature too high
Test built-in situation of the ventilation channel and
the function of the cooling fan
F7
Faulty electrical connection (only in appliances
with Prisma power electronics)
Correctly connect the appliance and re-start
F8
No connection between power electronics and
input electronics
Check connection line - replace electronic systems if
necessary
F9
Micro processor resets itself independently (=
Reset)
Execute network reset by disconnecting the
appliance from the electricity supply and restarting
F10
Triac on power electronics defect
Activate Main Button, select an operation modus
with hot air, wait for cooling ventilation start, replace
power electronics again in the event of an error report
following approximately 20 seconds
F11
Meat skewer sensor without contact or short-
circuited
Check meat thermometer, also check bushing and
wiring if necessary; if all this OK replace power
electronics
F91
Temperature sensor alarm for steam generator -
resulting in F12
Test temperature sensor, replace if necessary
F12
Temperature sensor of steam generator without
contact or short-circuited
Test temperature sensor, replace if necessary
F13
Internal electronics error
Replace power electronics
F14
software error
Replace input electronics
F15
Internal electronics error
Replace input electronics
F16
Combined alarm Pyrolytic cleaning/cooking zone
Replace input electronics
Alarmmanagement Powerboards Prisma, OVC1000 und OVC2000
Summary of Contents for Built-in appliances
Page 37: ... 37 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 2 Example circuit diagram OVC 1000 ...
Page 38: ... 38 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 3 Example circuit diagram OVC 2000 ...
Page 39: ... 39 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 4 Example circuit diagram SOEC ...
Page 40: ... 40 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 5 Example circuit diagram Prisma ...
Page 41: ... 41 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 6 Example circuit diagram HOC 2000 ...
Page 42: ... 42 DGS TDS N 05 09 A B Electrolux 599 518 252 EN 7 7 Operative Equipment Overview ...
Page 43: ... 43 DGS TDS N 05 09 A B Electrolux 599 518 252 EN Changes Pages 34 Chapter 6 1 changed ...