Fig. Door lock in unlocked state
2 – E Inlet unlocking
4 – Inlet lock
3 – Phase (230 V)
33/34 – Switch contacts (5 V, 100 mA)
unlocked
interlocked
As soon as a voltage of 230 V is applied to the contacts 3 and 4, the bar “A” moves to the other side
after 2 – 10 seconds and blocks the lock lever mechanically. The door cannot be opened. At the
same time, the internal contact “B” opens and disconnects the lock path. The switch contacts 33/
34 close and signal that door lock is completed. The electronic signal completes the lock signal.
Internal contact “C” closes.
For unlocking, a voltage of 230 V must be applied to contacts 2 and 3. The bar “A” moves
backwards and releases the lock lever. The door can be opened provided that the contact f11
(Klixon) is closed.