CONTENTS
Orifice, 1.40 mm
Orifice, 1.64 mm
Orifice, .68 mm
Label set
External natural gas regulator
TOOLS REQUIRED
3
/
4
" Socket
T-15 Torx bit
7 mm Socket
8 mm Socket
Clean gloves (pair)
Detergent solution (for leak testing)
These instructions describe reworking a Wolf
ICBCG152T/S or ICBCG152TF/S natural gas cooktop to
meet Australian specifications.
WARNING
To avoid serious burns and/or explosions, keep
combustibles away from the appliance whenever a flame
is present. Surfaces and components get hot during the
use of the appliance.
WARNING
Disconnect the product from the power source before
starting this procedure.
WARNING
Turn off the gas to the product at the supply source before
starting this procedure.
DISASSEMBLE THE UNIT
1
Remove the burner grate.
2
Remove both burner caps.
3
Remove both burner assemblies.
4
Remove the knobs.
5
Remove the bezels.
6
Remove the burner pan and glass panel.
REWORK THE UNIT TO AUSTRALIAN SPECIFICATIONS
1
For the front (9.2K) burner:
a)
Use an 8 mm socket to remove the main orifice
marked "158," along with its extension.
b)
Use a 7 mm socket to install the 1.40 mm orifice
directly into the main orifice holder (without the
extension).
2
For the rear (12K) burner:
a)
Use an 8 mm socket to remove the main orifice
marked "184," along with its extension.
b)
Use a 7 mm socket to install the 1.64 mm orifice
directly into the main orifice holder (without the
extension).
c)
Use a 7 mm socket to remove the simmer orifice
marked "65."
d)
Use a 7 mm socket to install the 0.68 mm orifice
into
the simmer orifice holder.
Orifice extension
GAS LEAK TESTING
WARNING
Never test for a gas leak with a flame.
1
Brush a liquid detergent solution onto all gas
connections, then open the gas valve.
2
If bubbles appear, close the valve and adjust
connections.
3
Check for leaks again.
4
Clean off the detergent solution.
ICBCG152T(F)/S Natural Gas Australia Rework
wolfappliance.com 800.222.7820
9029038 REV A 05/2019
Page 1 of 2
*9029038$REV$A*