background image

technical data

FEATURES

CHG642SA/WA

CHG646SA/WA

CHG956SA/WA

CHG606SA

72K315S/W

Brand

Chef

Chef

Chef

Chef

Simpson

Cooking zones

4

4

5

4

4

Wok

Yes

Yes

Yes

Yes

Yes

Ignition

1.5V battery

220-240V

220-240V

220-240V

220-240V

Trivet

Wire Gloss

Wire Matt

Wire Matt

Wire Matt

Wire Gloss

Hob material

Stainless Steel/

Enamelled White

Stainless Steel/

Enamelled White

Stainless Steel/

Enamelled White

Stainless Steel

Stainless Steel/

Enamelled White

Features

Ignition through knob Ignition through knob Ignition through knob

Ignition through knob

Ignition through knob

Flame safeguard

No

No

No

No

No

Gas Types

NG, (LP conversion 

kit supplied)

NG, (LP conversion 

kit supplied)

NG, (LP conversion 

kit supplied)

NG, (LP conversion kit 

supplied)

NG, (LP conversion 

kit supplied)

Cooktop dimension 

Width (mm)

600

600

860

600

600

Depth (mm)

535

535

510

535

535

Height (mm)

58

58

58

58

58

Cutout dimension

Width (mm)

570

570

830

570

570

Depth (mm)

490

490

470

490

490

Energy rating (NG) 

Small burner

5.1 MJ/h

5.1 MJ/h

5.1 MJ/h

5.1 

MJ/h

5.1 MJ/h

Medium burner

2 x 9.0 MJ/h

2 x 9.0 MJ/h

2 x 9.0 MJ/h

9.0 

MJ/h

2 x 9.0 MJ/h

Large burner

12.1 MJ/h

12.1 

MJ/h

Wok burner

14.4 MJ/h

14.4 MJ/h

14.4 MJ/h

14.4 

MJ/h

14.4 MJ/h

Total MJ/h

37.5 MJ/h

37.5 MJ/h

49.6 MJ/h

40.6 

MJ/h

37.5 MJ/h

technical data

FEATURES

SHG646SA

SHG956SA

GHR12S/W

GHR92S

WHG640SA/WA

Brand

Simpson

Simpson

Westinghouse

Westinghouse

Westinghouse

Cooking zones

4

5

4

5

4

Wok

Yes

Yes

No

Yes

No

Ignition

220-240V

220-240V

220-240V

220-240V

220-240V

Trivet

Wire Matt

Wire Matt

Wire Matt

Wire Matt

Wire Matt

Hob material

Stainless Steel

Stainless Steel

Stainless Steel/

Enamelled White

Stainless Steel

Stainless Steel/

Enamelled White

Features

Ignition through knob

Ignition through knob

Ignition through knob Ignition through knob Ignition through knob

Flame safeguard

No

No

No

No

No

Gas Types

NG, (LP conversion 

kit supplied)

NG, (LP conversion 

kit supplied)

NG, (LP conversion 

kit supplied)

NG, (LP conversion 

kit supplied)

NG, (LP conversion 

kit supplied)

Cooktop dimension 

Width (mm)

600

860

600

860

600

Depth (mm)

535

510

535

510

535

Height (mm)

58

58

58

58

58

Cutout dimension

Width (mm)

570

 830

570

830

570

Depth (mm)

490

470

490

470

490

Energy rating (NG) 

Small burner

5.1 MJ/h

5.1 MJ/h

5.1 MJ/h

5.1 MJ/h

5.1 MJ/h

Medium burner

2 x 9.0 MJ/h

2 x 9.0 MJ/h

2 x 9.0 MJ/h

2 x 9.0 MJ/h

2 x 9.0 MJ/h

Large burner

12.1 MJ/h

12.1 MJ/h

12.1 MJ/h

12.1 MJ/h

Wok burner

14.4 MJ/h

14.4 MJ/h

14.4 MJ/h

Total MJ/h

37.5 MJ/h

49.6 MJ/h

35.2 MJ/h

49.6 MJ/h

35.2 MJ/h

8  TECHNICAL DATA  Gas Cooktops  

Gas Cooktops  TECHNICAL DATA  9

Summary of Contents for 72K315S

Page 1: ...stallation Manual MODELS GHS607S W GHC607S W GHC617S W GHS917S W GHC937S W 72K315S W GHR12S W GHR92S WHG640SA WA CHG642SA WA CHG646SA WA CHG956SA WA CHG606SA SHG646SA SHG956SA WHG641SA WHG643SA WHG645SA WA WHG951SA WHG955SA WA ...

Page 2: ...pliance when it is in operation Do not store flammable materials in or under the appliance eg aerosols Do not modify this appliance Cooktops generally Do not allow pots to boil dry as damage to both pan and cooktop may result Do not operate the cooktop for an extended period of time without a pot or pan on the hotplate Do not allow large cookware to overhang the cooktop onto the adjacent benchtop ...

Page 3: ...t burner see Figure 2 Figure 2 OFF HI LOW Lighting burners Electronic ignition These cooktops are fitted with mains powered or battery ignition When the appliance has been connected and the power is on depressing any knob will release sparks to all burners except push button ignition see push button ignition models To light a burner depress the corresponding knob and turn to the HIGH position whil...

Page 4: ... released Knob not set between HIGH and LOW Knob MUST be set between these positions Knob not held down long enough in High position for flame safeguard where fitted to engage Repeat lighting procedure and hold knob down for 5 seconds in High position refer page 4 Low heat slow cooking Incorrect cooking pot or pan being used Refer to Figure 3 page 4 Benchtop or knobs overheating Incorrect cooking ...

Page 5: ...4 4 MJ h 14 4 MJ h Total MJ h 37 5 MJ h 37 5 MJ h 49 6 MJ h 40 6 MJ h 37 5 MJ h technical data FEATURES SHG646SA SHG956SA GHR12S W GHR92S WHG640SA WA Brand Simpson Simpson Westinghouse Westinghouse Westinghouse Cooking zones 4 5 4 5 4 Wok Yes Yes No Yes No Ignition 220 240V 220 240V 220 240V 220 240V 220 240V Trivet Wire Matt Wire Matt Wire Matt Wire Matt Wire Matt Hob material Stainless Steel Sta...

Page 6: ...ng codes electrical wiring regulations and any other relevant statutory regulations 3 The particular instructions as given below Before commencing installation check to ensure that the appliance gas type given on the data plate on the appliance corresponds with the type of gas to which it is intended the appliance be connected 4 A certificate of compliance MUST be given to the customer after the a...

Page 7: ...oint This is located on the regulator 3 Turn on the gas supply and electricity and try to ignite the gas TIPS INFORMATION tips information It will take additional time to light the gas for the first time as air needs to be purged from the pipes 4 With the appliance operating check the outlet pressure when all burners of the appliance are operating at maximum when the smallest burner of the applian...

Page 8: ...ating check the outlet pressure when all burners of the appliance are operating at maximum when the smallest burner of the appliance is operating at minimum Under these conditions the outlet pressure should not vary from the nominal outlet pressure of 2 60kPa by more than 0 52kPa 8 If the regulator appears to not be performing satisfactorily then check the following points If the outlet pressure i...

Page 9: ... that the correct procedure is understood WARNING warning Servicing must only be carried out by an authorised service person Injector sizes required for various gas types are shown in Table 3 page 14 The appliance inlet pressure for each gas type is also shown For model identification after installation an additional data plate sticker has been provided This sticker is to be stuck onto adjacent ca...

Page 10: ...ply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii failure to comply with any additional instructions supplied with the Appliance b the Appliance is modified without authority from Electrolux in writing c the Appliance s serial number or warranty seal has been removed or defaced d the Appliance was serviced or repaired b...

Page 11: ... into your Retailer phone or email our Customer Care team or visit our website Australia phone 1300 363 640 fax 1800 350 067 email customercare electrolux com au website chef com au Chef models westinghouse com au Westinghouse models New Zealand phone 0800 234 234 fax 0800 363 600 email customercare electrolux co nz website simpson co nz Simpson models westinghouse co nz Westinghouse models Top se...

Reviews: