Page 12
Conversion Back to Natural Gas
If it is necessary to return the cooktop to natural gas service, repeat all of the steps in this procedure using the
parts that have been removed. Use the chart below to determine the orifice sizes, shutter gaps, and the air
shutter part numbers.
Natural Gas Conversion Specifications
Burner
Location
Bypass Orifice
(X 100 mm)
Main Orifice
(X 100 mm)
Air Shutter
Part No.
Air Shutter
Gap
Left Rear
81
184
HN A-0053-E
.38/9.6
Left Front
72
135
HN A-0052-E
.09/2.3
Right Rear
72
135
HN A-0052-E
.09/2.3
Right Front
81
184
HN A-0053-E
.39/9.9
Center Rear
81
194
HN A-0053-E
.37/9.5
Center Front
81
194
HN A-0053-E
.38/9.7
Model E48GC76EPS (48-Inch)
Burner
Location
Bypass Orifice
(X 100 mm)
Main Orifice
(X 100 mm)
Air Shutter
Part No.
Air Shutter
Gap
Left Rear
81
184
HN A-0053-E
.37/9.5
Left Front
72
135
HN A-0052-E
.09/2.3
Right Rear
72
135
HN A-0052-E
.09/2.3
Right Front
81
184
HN A-0053-E
.37/9.4
Center Rear
81
194
HN A-0053-E
.37/9.5
Center Front
81
194
HN A-0053-E
.38/9.6