20
F2 Model Setting and Input and Output
Wiring Connection
1. Model setting: Set the toggle switch position
on the SR-5001K board.
Switch 1
→
ON,
Switch 2
→
ON,
Switch 3
→
ON,
Switch 4
→
OFF.
2. Input/output on SR-5001J board:
X8-1: AC220-240V power supply input
(power supply output of all relays)
X7-1: Switching on. The relay is picked to
output
the
power
supply
of
AC220-240V phase cable.
X7-2: Rinsing heating output control. The
relay is picked to output the power
supply of AC220-240V phase cable.
X7-3: Main washing heating output control.
The relay is picked to output the
power
supply
of
AC220-240V
phase cable.
X7-6: Main washing water pump output
control. The relay is picked to
output
the
power
supply
of
AC220-240V phase cable.
X8-5: Inlet electromagnetic valve output
control. The relay is picked to
output
the
power
supply
of
AC220-240V phase cable.
X8-6: Water drainage pump output control.
The relay is picked to output the
power
supply
of
AC220-240V
phase cable.
3. Input/output on SR-5001K board:
3.1. X5 plug block:
AC12V: Power supply input of SR-5001
series computer board (AC power supply input is
available: AC12V±20%)
。
3.2. X6 plug
+12V - 0V: If AC12V power supply input is
not available, DC power supply: DC12V±20%
may be used.
0V: common terminal (COM) for switch
signal input of S1 - S12.
3.3. X1 plug block:
X1-4: Water tank level signal input, switch of
water level OFF, water may be available.
X1-5: Door switch signal input, door closed,
and switch OFF.
3.4. X3/X4 plug block
X3-5/X4-5: Input of rinsing temperature
display sensor.
X3-4/X4-4: Input of rinsing temperature
control sensor.
X3-3/X3-4:
Input
of
main
washing
temperature sensor.
4. Communication cable, 4-core metallic STP