51
120
VAC.
Defective
thermal
limiter.
Defective
drive motor.
0.
Dryer completely
inoperative.
Measure the voltage
drop between terminal B of
the timer and neutral.
0.
120 VAC.
Turn the timer dial to 40
minutes of Timed Dry, close the
door & measure the voltage drop
between terminal C of the timer
and neutral
Defective household power
supply or broken wire be-
tween dryer terminal block
and terminal B of the timer.
Defective
timer.
Electric dryer completely inoperative.
Note: Always check wiring to the components.
0.
Measure the voltage drop
between terminal X of the
timer and neutral.
120 VAC.
0.
120 VAC.
Measure the voltage drop
between terminal M4 of the
motor and neutral.
120 VAC.
Defective
door sw.
Defective
start sw.
0.
Measure the voltage drop
between the terminal of the start
sw. with two wires to
it and neutral.
Defective
door sw.