29
0" (0 cm)
1" (2.54 cm)
NOTE:
Under counter and stack models - 0 inches (0 cm)
for sides, rear, and top.
CLOSET DOOR
1" (2.54 cm)
0" (0 cm)
UNDER COUNTER INSTALLATION
If an under counter* installation is desired, the dryer MUST have a top sheet
kit installed, P/N 131629100. Kit is available from an authorized parts
distributor.
*Custom-sized countertop is required.
0" (0 cm)
MOBILE HOME INSTALLATION
1. Dryer
MUST
be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting that
will not support combustion. Metal ducting must be 4
inches (10.16 cm) in diameter with no obstructions.
Rigid metal duct is preferred.
2. If dryer is exhausted through the floor and area beneath
the mobile home is enclosed, the exhaust system
MUST
terminate outside the enclosure with the
termination securely fastened to the mobile home
structure.
3. When installing a gas dryer into a mobile home, a
provision must be made for outside make up air. This
provision is to be not less than twice the area of the
dryer exhaust outlet.
4. This dryer
MUST
be fastened to the floor. Mobile Home
Installation Kit No. 169840 is available from your
dealer.
5. Refer to pages 2 and 3 for other important venting
requirements.
6. Installation
MUST
conform to current Manufactured
Home Construction & Safety Standard (which is a
Federal Regulation Title 24 CFR-Part 32-80) or when
such standard is not applicable, with American
60 SQ. IN.
(387.1 SQ.
60 SQ. IN.
(387.1 SQ. CM)
15"
(38.1 cm)
0" (0 cm)
0" (0 cm)