13
electrical cable sheathing, etc.) the operator for normal
machine use must:
F
TECHNICAL CHARACTERISTICS
F.1
Data table
MODELE
CLASSIC 1
CLASSIC 2
CLASSIC 3
Width
343 mm [13.5″]
642 mm [25.2″]
862 mm [33.9″]
Height
508 mm [20″]
508 mm [20″]
508 mm [20″]
Depth
568 mm [22.3″]
568 mm [22.3″]
568 mm [22.3″]
Weight
37 kg [81.5 Lbs]
55 kg [121.2 Lbs]
76 kg [167.5 Lbs]
110V single phase
1.7 kW
-
-
200V single phase
2.3 kW
3.5 kW (option 2.3)
3.5 kW
220V single phase
380V three neutral
2.7 kW
4.3 kW (option 2.7)
4.3 kW
230V single phase
400V three neutral
3 kW
4.7 kW (option 3)
4.7 kW
240V single phase
415V three neutral
3.2 kW
5.1 kW (option 3.2)
5.1 kW
Temperature
118 to 120
℃
/ 244 to 248
℉
Steam pressure
0.9 to 1 bar / 0.09 to 0.1 MPa
Pump pressure
9 bar / 0.9 MPa
High pressure valve
13 bar / 1.3 MPa
Low pressure valve
3.2 bar / 0.3 MPa
Dose of ground coffee
7 gr
Dose of water
5 to 7 cl
Infusion time
20 to 25 s
G
INSTALLATION & ASSEMBLY
G.1
Preparing the appliance
The appliance is delivered in a cardboard box and is screwed onto a wooden pallet.
Unpacking the appliance
• Cut the strapping.
• Open the crate and take out the box containing the accessories.
• Unscrew the nuts securing the appliance to the pallet.
• Separate the cardboard box from the pallet.
• Remove the appliance from the pallet and place it on wooden blocks.
• Remove the transport screws and washers.
Preparing the site and installing the appliance.
• Position the appliance in its final location, and level it with rubber washers if necessary.
• The appliance must be installed on a flat surface.
• It is necessary to leave a space of 50 mm [2″] at the back. Do not obstruct the air intakes provided on the top of the appliance.
• An earthed electric socket corresponding with the characteristics of the appliance and a water supply are enough.
• The canopies are put in place after the settings have been done.
• The appliance must not operate without its feet.
G.1.1
Fitting high feet (optional)
Reference feet :
54000
.
For fitting the high feet, once the appliance is installed in its location:
tip the appliance onto the front two feet to screw in the high feet at the base of the rubber feet at the back, and then do the same
operation for bolting the feet to the front.
G.2
Water connection
Water softener essential above 5° KH.
G.2.1
Water supply
• Pressure: 1 bar [0.1 MPa] and 8 bar [0.8 MPa]
• Connection: 3/8″ female gas (male fitting on the appliance)