17
on and the boiler level is set automatically. The water-intake
indicator blinks to show that the boiler is filling.
Heating:
When the water-intake indicator stops blinking, put the switch
on position 2 to start the heating process. When the correct
temperature has been reached, the steam pressure is
approximately 0.9 to 1 bar [0.09 to 0.1 MPa].
H.2
Keyboards
H.2.1
Electronic coffee box
1. Safety level control (by LED)
2. Continu/stop icon
3. Coffee icon (depends option chosen)
4. Coffee icon (depends option chosen)
5. Coffee icon (depends option chosen)
6. Coffee icon (depends option chosen)
7. Display
H.3
Programming
The icons from
to
can be programmed. The multiple
doses (1, 2 or 3 cups ) are calculated automatically from the
programming of one of them on each box:
• Set the machine switch to Position 0.
• Keep the icon
pressed and put again the machine on.
Display shows Pn then Pc and Pr by pressing several times the
key
.
H.3.1
Pc = Calculated programming
• Insert a filter-holder (with coffee) into the unit.
• Install cups.
Display shows Pc.
to
Select the dose to be programmed (2c for
example).
Start the infusion cycle.
Press again to stop when the amount of
coffee desired is correct.
Display of the corresponding digital value
(from 00 to 99).
• Repeat operation at 3 for the other doses (2C for example)
H.3.2
Pn = Digital programming
Quick programming without coffee and/or values carried
forward on other units.
Display shows Pn.
to
Select the dose to be programmed.
Display the digital value of the selected
dose.
Increase the value.
Reduce the value.
Memorize the new value.
Repeat operation at 4 for the other doses.
H.3.3
Pr = Manual programming
Same proceeding as in calculated programming Pc.
• The manual programming doesn’t calculate the other doses
(1, 2 or 3 cups), only the programmed dose is modified.
• Caution: any new programming (Pn or Pc) cancel ALL
previous programmed values.
• Wait until the program mode is automatically inactivated
(from 10 to 15s), or switch OFF and ON again the machine.
H.4
Configuration of different keyboards
H.4.1
2-cup units (type d2)
1. Safety level control (by LED)
2. Continu/stop icon
3. 2 large cup icon
4. 1 large cup icon
5. 2 small cup icon
6. 1 small cup icon
7. Display
H.4.1.1 Use and doses to programme
4 doses of coffee and 1 Continuous / Stop manual function are
available. During the infusion, the display indicates:
•
or
= 1 or 2 small cups
•
or
= 1 or 2 large cups
•
= Continuous / Stop
At any time, you can change the selection by pressing another
icon. The dosage is automatic but the infusion can be stopped
manually by pressing the Continuous / Stop icon.
Programming: as the multiple doses are calculated automati-
cally, two programming only are necessary (1c or 2c) and (1C
or 2C).
H.4.1.2 Configuration parameters
dn / dt
For the automatic calculation of multiple
doses:
dn = normal dose
dt = dosing with "Torino" kit
C0 / C1 / C2
timed for the infusion time:
C0 = no timer
C1 = display of the infusion time
C2 = display of dynamic time
A0 / A1
Authorization to programme:
A0 = programming prohibited
A1 = programming authorized
After switching on, the display shows, in order, the following
information:
• the version number of the electronic memory: eg. r1
• the type of unit: D2
• the active operating parameters: eg. dn, CO, A1
H.4.1.3 Modification of the configuration of parameters
• Shut down the appliance (0/1 switch).
2
1
6
7
5
4
3
3
6
2
2
2
3
6
2
2
2
3
6
2
6
3
2
2
1
6
7
5
4
3