Remove ICU: Slide out
Remove ICU:
Unlock pins top and bottom
Screen Message:
“No Communication – Touch to proceed”
Possible causes:
-
ICU board unplugged
:
Remove and re-seat in socket
-
Wrong software
installed in ICU board:
Load newest software
-
Reset ICU
Board
:
See below
-
Install new battery
CR1220:
Reset as above first
-
ICU board faulty
:
Replace ICU
Unplug Machine
!
Reset ICU Board instructions:
Remove board, remove battery, Ground battery clip by pressing until it touches lower
contact for 10 seconds. Wait 5 minute and re-install the battery.
Continued on next page:
ICU Board Reset