Installation manual
37
8.4
Table of pressure and adjustment
Liquied petro-
leum gases
Gas category
Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (
⌀
mm)
Air reducing
plate (mm)
Label number
May be avail-
able in follow-
ing countries
Butane mixture
/
Propane
mixture
3+
28-30 /
37
No regulation
1.80
Default
490375663
BE, CH, CY,
CZ, ES, FR,
GB, GR, IE, IT,
LT, LU, LV, PT,
SK, SI
Butane
3B/P
30, 37, 50
28
1.80
Default
490375664
BE, CY, DK,
EE, FI, FR, GB,
HU, IT, LT, NL,
NO, SE, SI, SK,
RO, HR, TR,
BG, IS, LU, MT,
PL, AT, CH, DE,
SK
Propane
3P
30, 37, 50
28
1.90
Default
490375665
FI, NL, RO, BE,
CH, CZ, IE, IT,
ES, FR, GR,
GB, HR, LT, NL,
PL, PT, SI, SK,
AT, CH, DE,
NL, LU, SK
Natural gas
Gas category
Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (
⌀
mm)
Air reducing
plate (mm)
Label number
May be avail-
able in follow-
ing countries
2H, 2E
20
8
3.30
Default
Default
AT, BG, CZ,
DK, EE, FI, GR,
HR, HU, IS, IE,
IT, LV, LT, NO,
PT, RO, SK, SI,
ES, SE, CH,
TR, GB, DE,
PL, LU
2E+
20 / 25
No regulation
2.60
471985370
490618501
BE, FR
2E (G20)
20
8
3.30
Default
490375662
NL
2L (G25)
25
12
2(43.46-45.3
MJ/m3 (0 °C))
(G25.3)
25
12
2LL
20
12
3.30
Default
490375662
DE
When a machine shall be installed or used on high altitude (2001 feet and higher) a kit for high altitude must be
installed.
For kit No. please refer to the spare parts list.