7
IMPORTANT SAFETY INSTRUCTIONS
Electric vehicle charger characteristics
1. The product must be connected
to AC supply power.
2. The product can be installed and
used in indoor and outdoor areas.
3. The product can be installed
on walls.
4. The Dock and charger together
are rated electrical protection
class IP I. The open dock
(i.e., without the charger) is rated
electrical protection class IP I.
Do not provide external GFCI on the supply power circuit as it may conflict with the internal GFCI of the charger.
General and electrical
specifications
Dock
Charging power
up to 7.6 kW (up to 32 A)
Mains input power
Dock:
240 Volt AC split phase, 40 A, 7.6 kW
Output power to charger
Dock:
240 Volt AC split phase, 32 A, 7.6 kW
maximum output depends on local distribution grid
Operating temperature
-22 °F to 122 °F (-30 °C to +50 °C) full load
Electrical Protection Class
I
Max. line cross-section
Max. supply line
(top or bottom):
7 AWG (10 mm²)
Certifications
UL and FCC certificate (tested and confirmed by a certified body)