12
Choosing the site
Consult the customer concerning the choice of a suitable
site. The optimal site for the charging station depends
on the owner’s needs and the parking and wiring
environment.
For masonry walls such as cinder block walls, for
example, use ¼" (6.35 mm) screw anchors. Ensure that
the screws used fit properly into the screw anchors and
are at least 2½" (63.5 mm) in length.
For wooden walls, use at least ¼" (6.35 mm) screws.
Ensure that the screws have a length of at least 2 ½"
(63.5 mm) and that the screws penetrate the wood at
least 2" (50.8 mm).
For hollow walls, connect at least two studs using a
channel stud for each height – top and bottom – of the
holes of the Dock, connect the studs using the associated
brackets. Ensure that the correct channel strut nuts are
used and use 5/16" (7.93 mm) screws with a length of at
least 2" (50.8 mm) so that the screws fully enter the
channel strut nuts.
When fastening the Dock with the screws, please
make sure that the screws are fastened tightly into the
bolt anchor / wall.
To ensure adequate heat dissipation and proper
functioning of the device, place the dock at a generous
distance from surrounding objects. We recommend
20", depending on ambient temperature.
DOCK INSTALLATION INSTRUCTIONS
DANGER
Do not install or use this
product in an area with
hazardous or flammable
materials or vapors.
Line selection
When selecting the cable for connection to a compatible
electrical AC power circuit, follow all national and local
laws, regulations, ordinances, codes and safety standards.
Routing the connecting cable
Route the cable of adequate conductor area to the
site chosen. Note that only cables not exceeding 7 AWG
(10 mm²) in size may be introduced into the Dock
(maximum bending radii). The routed cables may
therefore have to be rewired before they are inserted
into the Dock.
Once the required cables have been routed,
the pre-installation is complete.