![Electra LEX 12 Service Manual Download Page 33](http://html1.mh-extra.com/html/electra/lex-12/lex-12_service-manual_2378857033.webp)
7-1
ELECTRICAL DATA
Revision Y06-01
Service Manual - LEX
7. ELECTRICAL
DATA
7.1 Single
Units
MODEL
LEX 7
LEX 9
Power Supply
To indoor
To outdoor
To indoor
To outdoor
1PH-230V-50Hz 1PH-230V-50Hz
Max Current, (A)
4.3
6.0
Circuit Breaker,(A)
10.0
10.0
Power Supply Wiring.
(No. x Cross Section mm
2
)
3 x 1.5 mm
2
3 x 1.5 mm
2
Interconnecting Cable RC
Model
(No. x Cross Section mm
2
)
5 x 1.0 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
6 x 1.0 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
5 x 1.0 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
6 x 1.0 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
Interconnecting Cable ST Model
(No. x Cross Section mm
2
)
4 x 1.0 mm
2
5 x 1.0 mm
2
4 x 1.0 mm
2
5 x 1.0 mm
2
MODEL
LEX 12
LEX 14
Power Supply
To indoor
To outdoor
To indoor
To outdoor
1PH-230V-50Hz 1PH-230V-50Hz
Max Current, (A)
8.2
9.5
Circuit Breaker,(A)
15.0
15.0
Power Supply Wiring.
(No. x Cross Section mm
2
)
3 x 1.5 mm
2
3 x 1.5 mm
2
Interconnecting Cable RC
Model
(No. x Cross Section mm
2
)
5 x 1.5 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
6 x 1.5 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
5 x 1.5 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
6 x 1.5 mm
2
+ 2 x 0.5 mm
2
(OCT sensor)
Interconnecting Cable ST Model
(No. x Cross Section mm
2
)
4 x 1.5 mm
2
5 x 1.5 mm
2
4 x 1.5 mm
2
5 x 1.5 mm
2
NOTE
Power wiring cord should comply with local lows and electrical
regulations requirements.