11-13
CONTROL SYSTEM
Revision Y05-02
Service Manual - K DCI
1 = Close Jumper (connect jumper).
0 = Open Jumper (connect jumper).
Jumper –
Self test
J1
J1
OPERATION
OPERATION
Clock
0
NORMAL
SELF-TEST
1
0
Compensation Jumper – J2
Model
J2 (Default)
Compensation
Wall Mounted
0
Activated
Floor/Ceiling
1
Deactivated
Ducted/cassette
1
Activated
Family selection Jumper – J3, J4 and J5
Family
J5
J4
J 3
Reserved
Reserved
Reserved
Wall Mounted (WNG/FLO)
Floor/Ceiling (PXD)
Reserved
Ducted (LS)
Cassette (K)
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Model selection Jumper – J6, J7
J8 - Clock/Power Shedding
Model
J7 J6
9000 Btu/hr
12000 Btu/hr
18000 Btu/hr
24000 Btu/hr
0
0
0
1
1
0
1
1
J8
Power Shedding
1
J9 – IFAN Cycling Disabling
Display Mode
(wall mounted units only)
J9
LCD
0
LED
1
11.1 .
Indoor Unit Controller
2 1
11.12
Jumper Setting