PRODUCT DATA SHEET
2-3
SM PXD 1-E.3 GB
2.3
PXD 15 / ONG-14 R410A
Model Indoor Unit
PXD-15
Model Outdoor Unit
ONG-14
Installation Method of Pipe
Flared
Characteristics
Units
Cooling Only
Cooling
Heating
Capacity
(1)
Btu/hr
13990
13990
15350
kW
4.1
4.1 4.5
Power input
(1)
kW
1.355
1.355
1.380
EER (Cooling) or COP(Heating)
(1)
W/W
3.03 3.03
3.26
Energy efficiency class
B
B
C
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Rated current
A
6.4
6.4
6.5
Starting current
A
30
Circuit breaker rating
A
15
INDOOR
Fan type & quantity
Centrifugal x 2
Fan speeds
H/M/L
RPM
1000/780/720
Air flow
(2)
H/M/L
m3/hr
510/390/350
External static pressure
Min-Max
Pa
0
Sound power level
(3)
H/M/L
dB(A)
57/53/49
Sound pressure level
(4)
H/M/L
dB(A)
48/43/38
Moisture removal
l/hr
1.9
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
820x630 x190
Weight
kg
22
Package dimensions
WxHxD
mm
890x710x280
Packaged weight
kg
26
Units per pallet
units
14
Stacking height
units
7 levels
OUTDOOR
Refrigerant control
Capillary tube
Compressor type, model
Rotary, MITSUBISHI RN165VHSMT
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H/L
RPM
920
Air flow
H/L
m3/hr
2160
Sound power level
H/L
dB(A)
63
64
Sound pressure level
(4)
H/L
dB(A)
53
54
Dimensions
WxHxD
mm
795x610x290
Weight
kg
41.5
42.2
Package dimensions
WxHxD
mm
945x655x395
Packaged weight
kg
45.5
46.5
Units per pallet
Units
9
Stacking height
units
3 levels
Refrigerant type
R410A
Refrigerant chargless distance
kg/m
1.34kg/7.5m
Additional charge per 1 meter
g/m
7.5m<Lin<15m:+25g/m
Connections between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
1/2"(12.7)
Max. tubing length
m.
Max.15
Max. height difference
m.
Max.7
Operation control type
Remote control
Heating elements
kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
CONTENT
Summary of Contents for GC18 ST/RC
Page 58: ...WIRING DIAGRAMS 7 5 SM PXD 1 E 3 GB 7 9 Outdoor Unit OU7 24 OU8 30 3PH CONTENT...
Page 60: ...ELECTRICAL CONNECTIONS 8 2 SM PXD 1 E 3 GB 8 3 PX 18 24 30 3PH CONTENT...
Page 62: ...REGRIGERATION DIAGRAMS 9 2 SM PXD 1 E 3 GB 9 1 2 PXD 24 R410A CONTENT...
Page 63: ...REFRIGERATION DIAGRAMS 9 3 SM PXD 1 E 3 GB 9 1 3 PXD 24 OU7 24Z R410A CONTENT...
Page 64: ...REGRIGERATION DIAGRAMS 9 4 SM PXD 1 E 3 GB 9 1 4 PXD 30 R410A CONTENT...
Page 69: ...CONTROL SYSTEM 11 3 SM PXD 1 E 3 GB 11 1 4 Main PCB Controller CONTENT...
Page 110: ...EXPLODED VIEWS SPARE PARTS LISTS 13 5 SM PXD 1 E 3 GB 13 5 Indoor Unit PXD 18 24 30 CONTENT...
Page 114: ...EXPLODED VIEWS SPARE PARTS LISTS 13 9 SM PXD 1 E 3 GB 13 9 Outdoor Unit ONG 9 12 ST CONTENT...
Page 117: ...EXPLODED VIEWS SPARE PARTS LISTS 13 12 SM PXD 1 E 3 GB 13 12 Outdoor Unit ONG 9 12 RC CONTENT...
Page 120: ...EXPLODED VIEWS SPARE PARTS LISTS 13 15 SM PXD 1 E 3 GB 13 15 Outdoor Unit ONG 14 ST CONTENT...
Page 122: ...EXPLODED VIEWS SPARE PARTS LISTS 13 17 SM PXD 1 E 3 GB 13 17 Outdoor Unit ONG 14 RC CONTENT...
Page 124: ...EXPLODED VIEWS SPARE PARTS LISTS 13 19 SM PXD 1 E 3 GB 13 19 Outdoor Unit GC 18 ST CONTENT...
Page 126: ...EXPLODED VIEWS SPARE PARTS LISTS 13 21 SM PXD 1 E 3 GB 13 21 Outdoor Unit GC 18 RC CONTENT...
Page 159: ...APPENDIX A 15 1 SM PXD 1 E 3 GB APPENDIX A INSTALLATION AND OPERATION MANUAL CONTENT...