TROUBLESHOOTING
12-1
SM PXD 1-E.3 GB
12. TROUBLESHOOTING
No. SYMPTOM
PROBABLE
CAUSE
CORRECTIVE
ACTION
1 Power
supply
indicator
(Red LED) does not light
up.
No power supply.
Check power supply. If power
supply is OK, check display
and display wiring, if OK,
replace PCB.
2
Unit does not respond to
remote control command.
Remote control
command did not reach
the indoor unit.
Check remote control
batteries. If batteries are OK,
check display and display
wiring, if OK, replace PCB.
3 Unit
responds
to
remote
control command but
operate indicator (Green
LED) does not light up.
Problem with display
PCB.
Replace display PCB.
Unit in HEAT MODE and
coil is still not warm.
Change to COOL MODE and
check.
4
Indoor fan does not start
(louvers are opened and
Green LED lights up).
Problem with PCB or
capacitor.
Change to HIGH speed and
check power supply to motor is
higher than 130 VAC. If OK
replace capacitor, if not OK
replace controller.
5
Indoor fan works when
unit is OFF, and indoor fan
speed is not changed by
remote control command.
PCB problem.
Replace controller.
6 Compressor
does
not
start.
Electronics control
problem or protection.
Perform diagnostics, and
follow the actions described
below.
7
Compressor stops during
operation and Green LED
remains on.
Electronic control or
power supply problem.
Perform diagnostics, and
follow the actions described
below.
8 Compressor
is
ON
but
outdoor fan does not work.
Problem with outdoor
electronics or outdoor fan
capacitor.
Switch unit to COOL mode,
HIGH speed with 16 degrees
set point (summer) or HEAT
mode high speed with 30
degrees set point (winter).
Check power supply to motor
is higher than 130 VAC. If OK
replace capacitor, if not OK
replace controller.
9
Unit works in wrong mode
(cool instead of heat or
heat instead of cool).
Electronics or power
connection to RV.
Check RV power connections.
If OK, check RV operation with
direct 230 VAC power supply,
if OK, replace outdoor
controller.
10
All components are
operating properly but no
cooling or heating.
Refrigerant leak.
Check refrigeration system.
CONTENT
Summary of Contents for GC18 ST/RC
Page 58: ...WIRING DIAGRAMS 7 5 SM PXD 1 E 3 GB 7 9 Outdoor Unit OU7 24 OU8 30 3PH CONTENT...
Page 60: ...ELECTRICAL CONNECTIONS 8 2 SM PXD 1 E 3 GB 8 3 PX 18 24 30 3PH CONTENT...
Page 62: ...REGRIGERATION DIAGRAMS 9 2 SM PXD 1 E 3 GB 9 1 2 PXD 24 R410A CONTENT...
Page 63: ...REFRIGERATION DIAGRAMS 9 3 SM PXD 1 E 3 GB 9 1 3 PXD 24 OU7 24Z R410A CONTENT...
Page 64: ...REGRIGERATION DIAGRAMS 9 4 SM PXD 1 E 3 GB 9 1 4 PXD 30 R410A CONTENT...
Page 69: ...CONTROL SYSTEM 11 3 SM PXD 1 E 3 GB 11 1 4 Main PCB Controller CONTENT...
Page 110: ...EXPLODED VIEWS SPARE PARTS LISTS 13 5 SM PXD 1 E 3 GB 13 5 Indoor Unit PXD 18 24 30 CONTENT...
Page 114: ...EXPLODED VIEWS SPARE PARTS LISTS 13 9 SM PXD 1 E 3 GB 13 9 Outdoor Unit ONG 9 12 ST CONTENT...
Page 117: ...EXPLODED VIEWS SPARE PARTS LISTS 13 12 SM PXD 1 E 3 GB 13 12 Outdoor Unit ONG 9 12 RC CONTENT...
Page 120: ...EXPLODED VIEWS SPARE PARTS LISTS 13 15 SM PXD 1 E 3 GB 13 15 Outdoor Unit ONG 14 ST CONTENT...
Page 122: ...EXPLODED VIEWS SPARE PARTS LISTS 13 17 SM PXD 1 E 3 GB 13 17 Outdoor Unit ONG 14 RC CONTENT...
Page 124: ...EXPLODED VIEWS SPARE PARTS LISTS 13 19 SM PXD 1 E 3 GB 13 19 Outdoor Unit GC 18 ST CONTENT...
Page 126: ...EXPLODED VIEWS SPARE PARTS LISTS 13 21 SM PXD 1 E 3 GB 13 21 Outdoor Unit GC 18 RC CONTENT...
Page 159: ...APPENDIX A 15 1 SM PXD 1 E 3 GB APPENDIX A INSTALLATION AND OPERATION MANUAL CONTENT...