![Electra CN 25 DCI Service Manual Download Page 56](http://html.mh-extra.com/html/electra/cn-25-dci/cn-25-dci_service-manual_2378827056.webp)
11-9
CONTROL SYSTEM
SM CN 1-E.1 GB
11.1.16.2 Indoor Coil Defrost Protection — CN
ICT
Trend
Fast Increasing Increasing
No Change
Decreasing
Fast Decreasing
< -2
SC
SC
SC
SC
SC
[-2, 0)
D1
D1
D2
D2
D2
[0, 2)
SR
SR
D1
D2
D2
[2, 4)
SR
SR
SR
D1
D2
[4, 6)
Norm
Norm
SR
SR
D1
[6, 8]
Norm
Norm
Norm
SR
SR
> 8
Norm
11.1.16.3 Indoor Coil Overheating Protection
ICT
ICT Trend
Fast Decreasing
Decreasing
No Change
Increasing
Fast Increasing
>62
SC
SC
SC
SC
SC
[60, 62)
D1
D1
D2
D2
D2
[55, 60)
SR
SR
D1
D2
D2
[52, 55)
SR
SR
SR
D1
D2
[48, 52)
Norm
Norm
SR
SR
D1
[45, 48)
Norm
Norm
Norm
SR
SR
I<45
Norm
11.1.17
Compressor Overheating Protection
11.1.17.1 Compressor Overheating Protection for DCI25/35/50/60/72Z
Compressor temperature can be in one of 5 control zones (4 in protection, and 1 normal),
according to the following chart.
Normal
P1
P2
P3
Stop-Compressor
94
98
102
105
CTT
Control Status
Compressor Temperature Increases Else
P1
Normal
Stop Rise
P2
HzDown 1
Stop Rise
P3
HzDown 2
HzDown 1
Stop Compressor
Stop Compressor
CONTENT
Summary of Contents for CN 25 DCI
Page 15: ...4 2 OUTLINE DIMENSIONS SM CN 1 E 1 GB 4 2 Outdoor Unit DCI 50 4 3 Outdoor Unit DCI 60 CONTENT ...
Page 16: ...4 3 OUTLINE DIMENSIONS SM CN 1 E 1 GB 4 4 Outdoor Unit DCI 72Z CONTENT ...
Page 44: ...8 1 WIRING DIAGRAMS SM CN 1 E 1 GB 8 WIRING DIAGRAMS 8 1 CN 25 35 50 60 70 DCI CONTENT ...
Page 92: ...13 12 EXPLODED VIEWS AND SPARE PARTS LISTS SM CN 1 E 1 GB 13 11 Outdoor Unit DCI 60 CONTENT ...
Page 94: ...13 14 EXPLODED VIEWS AND SPARE PARTS LISTS SM CN 1 E 1 GB 13 13 Outdoor Unit DCI 72Z CONTENT ...