background image

Page 3

 

  

INTRODUCTION 

 

Congratulations on purchasing the most advanced high efficiency, 
microprocessor-controlled pool and spa heat pump available.  Your heater 

has been manufactured with the most state-of-the-art quality control 

equipment available today to ensure the highest quality product delivered to 

your door.  A heat pump pool heater is a highly efficient, cost effective 

method of pool heating.  Proper operation and care will result in many years 

of swimming enjoyment and pleasure. 
 

Your new pool heater is a self-contained unit designed specifically for 

swimming pool and spa heating.  It utilizes the sun’s free energy by 

extracting heat from the sun-warmed air and transferring it efficiently to the 

pool water.   Because your pool heater moves the free heat from the 
outside air to the pool, rather than create heat, as a fossil fuel or electric 

resistance heater does, it can heat your swimming pool or spa for up to 

80% less cost than these other less efficient methods. 

 

 As with all pool heating methods, you are advised to utilize a pool cover at 

night and when the pool is not in use.  The pool cover should be used if the 
night temperature is 15

°

F (8

°

C) less than the desired pool temperature.  

This will keep evaporation, the greatest source of heat loss, to a minimum, 

greatly reducing the overall pool heating costs.  During warmer weather, 

the pool cover may not be required. 

 

Your pool and spa heater combines simplicity with trouble-free 
performance.  As with most appliances, an understanding of proper 

operation of the heater is important.  Proper installation and operation 

increases efficiency and reduces heating costs.  Your pool heater is 

designed with features that make it simple to operate, maintain and service.  

Proper installation enhances these features and minimizes problems.  This 

manual will provide you with the information needed to properly install, 
operate and maintain your heater. 

 

Summary of Contents for Swimming Pool Heat Pump

Page 1: ...Swimming Pool Heat Pump Owner s Installation Operations Manual 5005001B Version 2 02...

Page 2: ...p 6 Bonding 7 Water Chemistry Maintenance 8 Heat Pump Features 9 Heat Pump Operation 10 Control On Off 10 Pool Spa Modes 10 Changing Set Point Temperature 11 Heater Running Time 11 Keypad Lockout 11 D...

Page 3: ...c resistance heater does it can heat your swimming pool or spa for up to 80 less cost than these other less efficient methods As with all pool heating methods you are advised to utilize a pool cover a...

Page 4: ...please take a moment and jot down the following information If you should ever need to call us for service or a question we will need this information Model Number ___________________________________...

Page 5: ...d through the evaporator coil and discharged through the top grill At least 4 feet clearance should be allowed above the unit for unrestricted air discharge The unit must not be installed under a porc...

Page 6: ...excessive pump head pressure is not indicated The recommended flow rate is 50 gpm through the heater For questions on multiple heater installations please contact our engineering department Multiple...

Page 7: ...equipment On some older pools this substructure bond wire may not exist In this case a 6 to 8 ft copper rod must be driven into the ground near the pool equipment and all electrical and metal compone...

Page 8: ...7 8 1 time per week Chlorine Concentration 1 0 to 3 PPM 1 time every 2 to 3 days Total Alkalinity 80 to 120 PPM 1 time every 2 to 3 weeks Total Dissolved Solids Below 2400 PPM 1 time per month Calcium...

Page 9: ...abilities ULTRA QUIET The unit is equipped with a low RPM fan motor in combination with a deep drawn venturi to ensure whisper quiet operation HIGH EFFICIENCY The heat pump utilizes the latest in comp...

Page 10: ...e two settings with the POOL SPA button located on the control When power is applied to the control it will turn on in the previous mode whether it is Pool Heat or Spa Heat When water is flowing throu...

Page 11: ...When you first run your heater it may need to run continuously for 24 to 48 hours to get the pool up to the desired temperature KEYPAD LOCKOUT While in any mode the user can lockout the keypad by pre...

Page 12: ...y build up Keep the drain holes in the base free of debris to assure proper condensate drainage Your heat pump s cabinet is made from a maintenance free rust free plastic that is UV resistant It will...

Page 13: ...TION POSSIBLE CAUSE POSSIBLE SOLUTION Control Display Blank No power supply to heater Tripped breaker or blown fuse Control failure Reset breaker Replace fuse If problem persists call factory for serv...

Page 14: ...Water sensor malfunction or not connected Call factory for service Pool is heating slowly or not getting up to temperature Low or restricted water flow through the heater Leak in plumbing allowing ai...

Page 15: ...eed help follow the instructions below Service can be obtained by calling Elecro Engineering Ltd 01438 749474 When asking for help or service please provide a detailed description of the problem your...