CARE & MAINTENANCE 

 

CLEANING 

There is not much maintenance that needs to be done on your heater.  

Making sure there is good airflow through the evaporator and proper 

drainage are the two main tasks.  A garden hose with low-pressure water 
flow can be used to clean the evaporator coil.  Keep all shrubs trimmed 

back away from the unit to allow sufficient airflow.   

 

CAUTION:  Make sure all power is disconnected to the heater prior 

to washing.   

 
Clean the coil as needed.  If located near the ocean, cleaning will need to 

be done regularly to remove salt and sand.  Use a very soft brush so as not 

to bend the coil fins with soapy water to remove any build up.  Keep the 

drain holes in the base free of debris to assure proper condensate 

drainage.  
 

Your heat pump’s cabinet is made from a maintenance-free, rust-free plastic 

that is UV resistant.  It will last for years and any dirt or dust may simply be 

wiped away with a cloth or sprayed off with a water hose.  The use of a 

product such as Armor- All will restore its natural luster.  

DO NOT USE CLEANERS THAT CONTAIN ALCOHOL.  
Alcohol based cleaners may damage the plastic.
 

 

WINTERISING 

In areas where freezing condition is not prevalent and winterizing of pools is 

not common, allow water to flow through the heater even when not in use. 

 

In freezing areas, it is mandatory that the water be completely 

drained from the heater and disconnected from the piping.  The 

heat exchanger must be blown out with air to ensure no water in 
the heat exchanger. 

Summary of Contents for Swimming Pool Heat Pump

Page 1: ...Swimming Pool Heat Pump Owner s Installation Operations Manual 5005001B Version 2 02...

Page 2: ...p 6 Bonding 7 Water Chemistry Maintenance 8 Heat Pump Features 9 Heat Pump Operation 10 Control On Off 10 Pool Spa Modes 10 Changing Set Point Temperature 11 Heater Running Time 11 Keypad Lockout 11 D...

Page 3: ...c resistance heater does it can heat your swimming pool or spa for up to 80 less cost than these other less efficient methods As with all pool heating methods you are advised to utilize a pool cover a...

Page 4: ...please take a moment and jot down the following information If you should ever need to call us for service or a question we will need this information Model Number ___________________________________...

Page 5: ...d through the evaporator coil and discharged through the top grill At least 4 feet clearance should be allowed above the unit for unrestricted air discharge The unit must not be installed under a porc...

Page 6: ...excessive pump head pressure is not indicated The recommended flow rate is 50 gpm through the heater For questions on multiple heater installations please contact our engineering department Multiple...

Page 7: ...equipment On some older pools this substructure bond wire may not exist In this case a 6 to 8 ft copper rod must be driven into the ground near the pool equipment and all electrical and metal compone...

Page 8: ...7 8 1 time per week Chlorine Concentration 1 0 to 3 PPM 1 time every 2 to 3 days Total Alkalinity 80 to 120 PPM 1 time every 2 to 3 weeks Total Dissolved Solids Below 2400 PPM 1 time per month Calcium...

Page 9: ...abilities ULTRA QUIET The unit is equipped with a low RPM fan motor in combination with a deep drawn venturi to ensure whisper quiet operation HIGH EFFICIENCY The heat pump utilizes the latest in comp...

Page 10: ...e two settings with the POOL SPA button located on the control When power is applied to the control it will turn on in the previous mode whether it is Pool Heat or Spa Heat When water is flowing throu...

Page 11: ...When you first run your heater it may need to run continuously for 24 to 48 hours to get the pool up to the desired temperature KEYPAD LOCKOUT While in any mode the user can lockout the keypad by pre...

Page 12: ...y build up Keep the drain holes in the base free of debris to assure proper condensate drainage Your heat pump s cabinet is made from a maintenance free rust free plastic that is UV resistant It will...

Page 13: ...TION POSSIBLE CAUSE POSSIBLE SOLUTION Control Display Blank No power supply to heater Tripped breaker or blown fuse Control failure Reset breaker Replace fuse If problem persists call factory for serv...

Page 14: ...Water sensor malfunction or not connected Call factory for service Pool is heating slowly or not getting up to temperature Low or restricted water flow through the heater Leak in plumbing allowing ai...

Page 15: ...eed help follow the instructions below Service can be obtained by calling Elecro Engineering Ltd 01438 749474 When asking for help or service please provide a detailed description of the problem your...

Reviews: