background image

®

MCD SPA OZONE GENERATOR

INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

MCD-250SE-01

4-2602-01 Rev.D

C-M-P.COM/DEL

Summary of Contents for CMP MCD-250SE-01

Page 1: ...MCD SPA OZONE GENERATOR INSTALLATION INSTRUCTIONS PRODUCT MANUAL MCD 250SE 01 4 2602 01 Rev D C M P COM DEL...

Page 2: ...tural elements rain sun sprinklers Mount the MCD so that it is inaccessible to anyone in the spa MCD must be located or fixed so that it cannot fall into the bath Mount the MCD cord facing downward In...

Page 3: ...Plumbing Vacuum System 1 7 Plumbing Ozone Generator 2 8 Electrical 2 9 Operation 3 10 Installation Complete 3 SECTION 2 Maintenance 1 Remove the MCD From Your Spa 4 2 Install the New MCD 4 Troubleshoo...

Page 4: ...on Manual One 1 check valve Five 5 feet of tubing Four 4 hose clamps 3 Installation Tools and Materials a Phillips Screwdriver b Pliers c Scissors 4 Unit Assembly All models are pre assembled and read...

Page 5: ...ck valve in the tubing Observe the flow arrow on the check valve and ensure that the flow direction is into the vacuum source d Secure all tubing connections with the hose clamps 8 Electrical a Test t...

Page 6: ...ator is turned on cover must be removed to view light c Verify that gas is flowing into the injector there should be no water in the tubing d Verify that water does not push past the check valve durin...

Page 7: ...he spa b Disconnect the ozone tubing from the MCD outlet hose barb c Open the spa controller panel and disconnect the MCD power cord d Remove the mounting screws and remove the MCD from the spa e Disc...

Page 8: ...OZONE GENERATOR COMPONENT LOCATIONS Cover removed for clarity Cover Power Supply Ozone Cell Ozone Outlet Figure 2 MCD Component Locations Ozone Generator Mounting Screw Locations LED Light Air Filter...

Page 9: ...1 Chlorine like odor 2 Burning sensation in eyes 1 Combined chlorine 2 pH out of balance 1 Balance pH to 7 2 7 6 2 Superchlorinate Colored Water 1 Water in newly filled spa turns black blue or brown...

Page 10: ...7 REPLACEMENT PARTS CMP P N DESCRIPTION 1 2 0078 HOSE CLAMP 4 REQUIRED 2 7 0075 OZONE TUBING 5 FT REQUIRED 3 7 1140 01 CHECK VALVE 1 3 2...

Page 11: ..._________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number _______...

Page 12: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 0721AB...

Reviews: