When installing and using the DEL MCD Spa Ozone Generator, basic safety precautions 

should always be followed. Be sure all the electrical power is shut OFF at the main 

circuit breaker before installing the MCD.

READ AND FOLLOW ALL INSTRUCTIONS.

All permanent electrical connections should be made by a qualified electrician.

Follow all applicable electrical codes.

Be sure all the electrical power is shut off at the main circuit breaker before installing 

the MCD.

If the MCD electrical connections will be attached directly to the spa controls, be 

sure the spa controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If 

the MCD is connected to an independent electrical supply, then a G.F.C.I. must be 

installed between the MCD and the electrical supply.

Do not bury cord.

WARNING

To reduce the risk of electric shock, replace the unit immediately if 

the cord is damaged.

The MCD must be mounted indoors or, under a cover, sheltered from natural 

elements (rain, sun, sprinklers). 

Mount the MCD so that it is inaccessible to anyone in the spa.

MCD must be located or fixed so that it cannot fall into the bath.

Mount the MCD cord facing downward.

Install a check valve in the tubing between the MCD and the vacuum source.

Plastic ozone supply tubing is supplied with the MCD. Never replace this tubing with 

metal tubing.

Do not operate the MCD unless sufficient air flow is being drawn through the unit.

WARNING

Short term inhalation of high concentrations of ozone and a long 

term inhalations of low concentrations of ozone can cause harmful physiological 

effects. Do not inhale ozone gas produced by this device.

This appliance can be used by children aged from 8 years and above and persons 

with reduced physical, sensory or mental capabilities or lack of experience and 

knowledge if they have been given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved. Children shall not play 

with the appliance. Cleaning and user maintenance shall not be made by children 

without supervision.

SAVE THESE INSTRUCTIONS!

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for CMP MCD-250SE-01

Page 1: ...MCD SPA OZONE GENERATOR INSTALLATION INSTRUCTIONS PRODUCT MANUAL MCD 250SE 01 4 2602 01 Rev D C M P COM DEL...

Page 2: ...tural elements rain sun sprinklers Mount the MCD so that it is inaccessible to anyone in the spa MCD must be located or fixed so that it cannot fall into the bath Mount the MCD cord facing downward In...

Page 3: ...Plumbing Vacuum System 1 7 Plumbing Ozone Generator 2 8 Electrical 2 9 Operation 3 10 Installation Complete 3 SECTION 2 Maintenance 1 Remove the MCD From Your Spa 4 2 Install the New MCD 4 Troubleshoo...

Page 4: ...on Manual One 1 check valve Five 5 feet of tubing Four 4 hose clamps 3 Installation Tools and Materials a Phillips Screwdriver b Pliers c Scissors 4 Unit Assembly All models are pre assembled and read...

Page 5: ...ck valve in the tubing Observe the flow arrow on the check valve and ensure that the flow direction is into the vacuum source d Secure all tubing connections with the hose clamps 8 Electrical a Test t...

Page 6: ...ator is turned on cover must be removed to view light c Verify that gas is flowing into the injector there should be no water in the tubing d Verify that water does not push past the check valve durin...

Page 7: ...he spa b Disconnect the ozone tubing from the MCD outlet hose barb c Open the spa controller panel and disconnect the MCD power cord d Remove the mounting screws and remove the MCD from the spa e Disc...

Page 8: ...OZONE GENERATOR COMPONENT LOCATIONS Cover removed for clarity Cover Power Supply Ozone Cell Ozone Outlet Figure 2 MCD Component Locations Ozone Generator Mounting Screw Locations LED Light Air Filter...

Page 9: ...1 Chlorine like odor 2 Burning sensation in eyes 1 Combined chlorine 2 pH out of balance 1 Balance pH to 7 2 7 6 2 Superchlorinate Colored Water 1 Water in newly filled spa turns black blue or brown...

Page 10: ...7 REPLACEMENT PARTS CMP P N DESCRIPTION 1 2 0078 HOSE CLAMP 4 REQUIRED 2 7 0075 OZONE TUBING 5 FT REQUIRED 3 7 1140 01 CHECK VALVE 1 3 2...

Page 11: ..._________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number _______...

Page 12: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 0721AB...

Reviews: