3
9. Operation
a. With the spa filled to the proper level, run the spa controller
through several cycles.
b. Verify that the Ozone Generator turns on and off as required by
the controller: LED light will illuminate when the ozone generator is
turned on (cover must be removed to view light).
c. Verify that gas is flowing into the injector (there should be no water
in the tubing).
d. Verify that water does not push past the check valve during any spa
cycle.
e. Check for and correct any leaks.
10. Installation Complete
a. Once properly installed, the Ozone Generator requires no further
user operation. It will operate automatically with the spa system.
SECTION 1 Installation