MANUAL ELDES ESIM364 V1.2
29
1. In order to instantly turn ON a specified PGM output and keep it in this state for a determined time period, send
the following SMS text message to the system’s phone number from any out of 10 preset user phone numbers:
SMS text message content:
ssss_Coo:ON:hr.mn:sc
or
ssss_out-name:ON:hr.mn:sc
Value:
oo
– PGM output number, range – [1... 76];
hr
– hours, range – [00... 23],
mn
– minutes, range – [00... 59];
sc
– seconds, range – [00... 59];
out-name
– PGM output name.
Example:
1111_Pump:ON
2. In order to instantly turn OFF a specified PGM output and keep it in this state for a determined time period,
send the following SMS text message to the system’s phone number from any out of 10 preset user phone
numbers:
SMS text message content:
ssss_Coo:OFF:hr.mn:sc
or
ssss_out-name:OFF:hr.mn:sc
Value:
oo
– PGM output number, range – [1... 76];
hr
– hours, range – [00... 23],
mn
– minutes, range – [00... 59];
sc
– seconds, range – [00... 59];
out-name
– PGM output name.
Example:
1111_C3:OFF:13.25:56
3. The system will reply with confirmation by SMS text message to the user phone number that sent the SMS text
message.
SMS
Fig. No. 35
User
ESIM364
SMS
SMS
3.12 Turning ON/OFF the Electrical Appliances for a Determined Time Period
NOTE:
PGM output can be turned ON for a determined time period only when it is in OFF state.
NOTE:
PGM output can be turned OFF for a determined time period only when it is in ON state.
3.13 Viewing Event Log
This feature allows to chronologically register up to 500 timestamped records regarding the following system events:
• System start.
• System arming/disarming.
• Zone violated/restored.
• Tamper violated/restored.
• Zone bypassing.
• Wireless device management.
• Temperature deviation by MIN and MAX boundaries.
• System faults.
The event log is of
LIFO (last in, first out)
type that allows the system to automatically replace the oldest records with the the latest
ones.
EKB2
Navigate through the following menu path using OK and arrow keys and enter user password to view the event log:
Menu path:
OK
→
VIEW EVENT LOG
→
OK
→
uuuu
→
OK
Value:
uuuu
4digit user password.