22
The built-in EKB3/EKB3W buzzer emits short beeps continuously and ESIM364 buzzer (if any) emits a steady beep in
case of alarm. In addition, the violated zone number is indicated by illuminated zone LED or flashing indicator
SYSTEM
(if the violated zone number is above 12). The violated tamper number is indicated by illuminated indicator
SYSTEM
.
The buzzer can be silenced by disarming the system using any method.
For more details on EKB3/EKB3W violated high-numbered zone & tamper number indication, please refer to chapter
3.10
Indication of System Faults.
By default configuration, the siren/bell (if any) provides continuous alarm sound for 1 minute in case of alarm. The fire
alarm is indicated by pulsating siren/bell alarm sound. The alarm sound can be silenced by disarming the system using
anymethod.
3.5 Bypassing & Activating Zones
Arming the system is disabled while there’s at least 1 violated zone. Bypassing allows to temporally deactivate a certain violated zone
and arm the alarm system afterwards.
NOTE
: Zones can only be bypassed and activated when the system is not armed.
EKB2
EKB2
EKB3
EKB3
NOTE
: The zone will stay bypassed until the system is disarmed. Once the system is disarmed, the zone‘s current state will be
indicated on the keypads.
ATTENTION
: Bypassing a violated tamper is NOT allowed. Please, restore the tamper (for example: close sensor‘s enclosure)
before arming the system
The built-in EKB2 buzzer and ESIM364 buzzer (if any) provide short beeps continuously in case of alarm. In addi
tion, the LCD screen back-light level is boosted and the alarm message (depending on violated zone type or tamper
violation) is displayed in the main screen view of EKB2 screen. The buzzer can be silenced by disarming the system
using any method. Navigate through the following menu path using
OK
and arrow keys to view the violated zone or
tamper number:
Menu path:
OK
→
VIOLATED ZONES
→
OK
→
ZONE 1... 76
OK
→
VIOLATED TAMPERS
→
OK
→
TAMPER 1... 76
Navigate through the following path using OK and arrow keys to bypass a violated zone (-s):
Menu path:
OK
→
BYPASS
→
OK
→
BYPASS LIST 1... 3
→
OK
→
ZONE 1... 76
→
OK
→
BYPASS
→
OK
OK
→
BYPASS
→
OK
→
BYP VIOLATED ZONES
→
OK
Navigate through the following path using OK and arrow keys to activate a bypassed zone:
Menu path:
OK
→
BYPASS
→
OK
→
BYPASS LIST 1... 3
→
OK
→
ZONE 1... 76
→
OK
→
UNBYPASS
→
OK
Bypass a violated zone by entering the following combination using [BYPS], number and [#] keys:
Press the [BYPS] key, enter zone number & user password:
BYPS nn uuuu #
Value:
nn
– zone number, range – [01... 76];
uuuu
– 4digit user password.
Example:
BYPS051111#
Bypass a zone:
Bypass all zones:
Activate a bypassed zone:
View violated zone:
View violated tamper: