14
1. To arm the system, enter any out of 30 available 4-digit user passwords using the number keys:
Enter user password (and select partition):
If only 1 partition is enabled:
uuuu
→
OK
→
If more than 1 partition is enabled:
uuuu
→
OK
→
[p] partname
→
OK
Value:
uuuu
– 4digit user password;
p
– partition number, range – [1... 4],
part-name
– up to 15 characters
partition name.
Example:
1111
→
OK
→
[2] PART2
→
OK
2. The system will initiate the exit delay countdown (by default – 15 seconds) intended for user to leave the secu
red area. The exit delay is indicated by short beeps emitted by keypad buzzer, buzzer connected to the alarm
system (if any) and
icon displayed next to the countdown timer on EKB2 keypad screen.
3. When the system is successfully armed, it will reply with confirmation by SMS text message to User 1 phone
number (by default) and the keypad will display icon on the screen for 5 seconds and switch to home scre
en view.
4. When attempting to arm the system in case of violated zone / tamper presence, the system will reply with
violated zone / tamper number. For more details, please refer to chapter
3.5 Bypassing & Activating Zones
.
1. The system will initiate the entry delay countdown (by default – 15 seconds) after the user has entered the
secured area. Entry delay countdown is intended for user to enter a valid user password before the alarm is
caused. The countdown is indicated by short beeps emitted by keypad buzzer and by long steady beep emit
ted by buzzer connected to the alarm system (if any).
2. To disarm the system or turn off the alarm, enter any out of 30 available 4-digit user passwords using the num
ber keys:
Enter user password (and select partition):
If only 1 partition is enabled:
uuuu
→
OK
→
If more than 1 partition is enabled:
uuuu
→
OK
→
[p] partname
→
OK
Value:
uuuu
– 4digit user password;
p
– partition number, range – [1... 4],
part-name
– up to 15 characters
partition name.
Example:
1111
→
OK
→
[2] PART2
→
OK
3. When the system is successfully armed, it will reply with confirmation by SMS text message to User 1 phone
number (by default) and if:
• only 1 partition is enabled, the keypad will display
icon on the screen for 5 seconds and switch to home
screen view.
• more than 1 partition is enabled, the keypad will display
part-name DISARMED
message on the screen for
3 seconds and switch to partition selection menu.
EKB2
EKB2
3.2.4 Arm by EKB2 Keypad
3.2.5 Disarm & Turn off the Alarm by EKB2 Keypad
Fig. No. 10
Fig. No. 11
1
7
4
2
8
5
0
3
9
6
1
7
4
2
8
5
0
3
9
6