MANUAL ELDES ESIM364 V1.2
23
3.6 Viewing System Information
See also
3.9 Managing Temperature Information.
3.7 Managing Periodical System Information
NOTE:
Unlike system information SMS text message upon request, periodical system information SMS text message does not
included zone states, PGM output names and status.
1. By default configuration, the SMS text message mentioned in chapter
3.6 Viewing System Information
is
sent periodically to User 1 phone number at 11:00 daily.
2. In order to set a different SMS sending frequency (in days) and time, send the following SMS text message to
the system‘s phone number from any out of 10 preset user phone numbers:
SMS text message content:
ssss_INFO:ff.tt
Value:
ff
– frequency in days, range – [0... 10];
tt
– time, range – [0... 23]
Example:
1111_INFO:2.15 (every 2nd day at 15:00)
1. In order to find out the system‘s current information, send the following SMS text message to the system‘s
phone number from any out of 10 preset user phone numbers:
SMS text message content:
ssss_INFO
Example:
1111_INFO
2. The system will reply to the user phone number that sent the SMS text message with the following up-to-date
information:
• System date & time.
• System status: partition armed (ON)/disarmed (OFF).
•
GSM signal strength level.
•
Main power supply status.
• Temperature of the area surrounding ESIM364 primary & secondary temperature sensors (if any).
• State of zones (OK/alarm).
SMS
SMS
Fig. No. 28
User
ESIM364
SMS
SMS
Fig. No. 29
User
ESIM364
SMS