1.   Arm the system in Stay mode manually by entering the following combination using [STAY] and number keys:

Press the [STAY] key & enter user password:

STAY uuuu

Value: 

uuuu

 ­ 4­digit user password

Example: 

STAY

1111

2.   When the system is successfully armed, it will reply with confirmation by SMS text message to User 1 phone 

number (by default).

For more details on how to disarm & turn off the alarm by EKB3/EKB3W keypad, please refer to chapter 

3.2.7 Disarm & 

Turn off the Alarm by EKB3/EKB3W Keypad

.

3.3.2 Arm by EKB3/EKB3W Keypad in STAY Mode Manually

Fig. No. 25

Summary of Contents for ESIM364

Page 1: ...GSM ALARM AND MANAGEMENT SYSTEM ESIM364 USER MANUAL ...

Page 2: ...t of short circuit or over current condition Open circuit breaker must have a gap between con nections of more than 3mm and the disconnection current 5A Mains power and backup battery must be disconnected before any installation or tuning work starts The system installa tion or maintenance must not be done during stormy conditions Backup battery must be connected via the connection which in the ca...

Page 3: ...d distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this GSM alarm and management system ESIM364 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 E...

Page 4: ...on of main definitions which are met in this user manual Definition Description System alarm system ESIM364 device SMS Short Message Service text Keypad Device with a set keys allowing to configure control the system view violated zones system faults EKB2 Model of wired LCD keypad EKB3 Model of wired LED keypad EKB3W Model of wireless LED keypad User phone number User 1 10 Phone number of the user...

Page 5: ...m Fault Indi cation Custom Keypad Partition Title Digital Clock Temperature Icon Message Description Delay zone violated when system is disarmed Exit delay countdown initiated System is armed and menu is locked System is disarmed and menu is unlocked CONFIGURATION MODE Configuration Mode activated BURGLARY ALARM Delay Instant or Follow zone violated when system is armed Icon Message Description 24...

Page 6: ...ery dead or missing battery failed siren failed GSM jammer detected date time not set GSM connection failed GSM antenna failed Audio Indication The built in buzzer uses two types of sound signals three short beeps and one long beep Three short beeps stand for successfully carried out configuration command one long beep for invalid configuration command In addition the buzzer emits short beeps in c...

Page 7: ...pply is lost low battery battery dead or missing battery failed siren failed GSM jammer detected date time not set GSM connection failed GSM antenna failed Audio Indication The built in buzzer uses two types of sound signals three short beeps and one long beep Three short beeps stand for successfully carried out configuration command one long beep for invalid configuration command In addition the ...

Page 8: ...ion Unshielded BUZ Maximum Current of Mini Buzzer 150mA BUZ Power Supply Voltage of Mini Buzzer 5V DC BUZ Cable Type for Mini Buzzer Connection Unshielded Dimensions 140x100x18mm Operating Temperature Range 20 550 C Supported Temperature Sensor Model Maxim Dallas DS18S20 DS18B20 Maximum Supported Number of Temperature Sensors 8 DATA Maximum Cable Length for 1 Wire Communication up to 30 meters DAT...

Page 9: ...r connection 5V Temperature sensor power supply terminal 5V MIC Microphone negative terminal MIC Microphone positive terminal BUZ Buzzer negative terminal BUZ Buzzer positive terminal C1 C4 PGM output terminals Z1 Z6 Security zone terminals Y RS485 interface for communication yellow wire G RS485 interface for communication yellow wire COM Common return terminal BELL Siren negative terminal BELL Si...

Page 10: ...r 5 6KΩ end of line resistor 5 6KΩ end of line resistor with nor mally closed contact and 3 3KΩ end of line resistor with normally closed contact Fig No 3 Fig No 2 2 3 Wiring Diagrams 2 3 1 General Wiring 2 3 2 Zone Connection Types C O M BELL BELL G Y C2 AUX AUX AC DC AC DC Z1 C O M Z2 Z3 C O M Z4 DATA 5V MIC MIC BUZ C1 BUZ C O M C O M Z6 Z5 MIC BUZ SIREN BELL iButton key reader Temperature senso...

Page 11: ...desired menu section EKB2 menu type is circle therefore when the last section in the menu list is selected you will be brought back to the beginning of the list after touching the key In this user manual the menu path is provided under tree view by starting at home screen view In this user manual valid parameter range is indicated in brackets The system configuration and control by EKB3 EKB3W keyp...

Page 12: ...e system rejects the phone call after 2 rings when disarming the system rejects the phone call immediately 2 When the system is successfully armed or disarmed it will reply with confirmation by SMS text message to the user phone number that made a phone call 3 When attempting to arm the system in case of violated zone tamper presence the system will reply with viola ted zone tamper number For more...

Page 13: ...t will reply with confirmation by SMS text message to the user phone number that sent the SMS text message 1 Leave the secured area 2 To arm the system send the following SMS text message to the system s phone number from any out of 10 preset user phone numbers SMS text message content ssss_ARMp or ssss_ARMp p p p Value p partition number range 1 4 Example 1111_ARM1 3 When the system is successful...

Page 14: ...he system will initiate the entry delay countdown by default 15 seconds after the user has entered the secured area Entry delay countdown is intended for user to enter a valid user password before the alarm is caused The countdown is indicated by short beeps emitted by keypad buzzer and by long steady beep emit ted by buzzer connected to the alarm system if any 2 To disarm the system or turn off t...

Page 15: ...ter any out of 30 available 4 digit user passwords using the number keys Enter user password uuuu Value uuuu 4 digit user password Example 1111 2 The system will initiate the exit delay countdown by default 15 seconds intended for user to leave the secu red area The countdown is indicated by short beeps provided by keypad built in buzzer if any 3 When the system is successfully armed it will reply...

Page 16: ...er by any out of 5 iButton keys 2 The system will initiate the exit delay countdown by default 15 seconds intended for user to leave the secu red area The countdown is indicated by short beeps provided by ESIM364 buzzer if any 3 When the system is successfully armed it will reply with confirmation by SMS text message to User 1 phone number by default 4 When attempting to arm the system in case of ...

Page 17: ...darea 3 When the system is successfully armed it will reply with confirmation by SMS text message to User 1 phone number by default 4 When attempting to arm the system in case of violated zone tamper presence the system will reply with violated zone tamper number For more details please refer to chapter 3 5 Bypassing Activating Zones 3 2 10 Arm by EWK1 Wireless Key fob Arm the system Fig No 20 Fig...

Page 18: ...own is intended for user to enter a valid user password before the alarm is caused 2 To disarm the system or turn off the alarm press 1 out of 4 EWK1 buttons by default button assigned to disarm the alarm system 3 When the system is successfully disarmed it will reply with confirmation by SMS text message to User 1 phone number by default Disarm the system Fig No 22 Fig No 23 User ESIM364 SMS EWK1...

Page 19: ...ed and restored during exit delay countdown when arming the system Manual The system goes into Stay mode after the user opens an additional menu or presses STAY key and enters a valid user password by EKB2 and EKB3 EKB3W keypad respectively There is no exit delay countdown when activating Stay mode manually Stay mode status is indicated in the home screen view of EKB2 Stay mode is NOT activated wh...

Page 20: ... uuuu 4 digit user password Example STAY1111 2 When the system is successfully armed it will reply with confirmation by SMS text message to User 1 phone number by default For more details on how to disarm turn off the alarm by EKB3 EKB3W keypad please refer to chapter 3 2 7 Disarm Turn off the Alarm by EKB3 EKB3W Keypad 3 3 2 Arm by EKB3 EKB3W Keypad in STAY Mode Manually Fig No 25 ...

Page 21: ...en on his her mobile phone to what is happening in area surrounding ESIM364 unit This feature is pro vided by a microphone if any connected to ESIM364 The phone call is made to the next preset user presumably to User 2 in a row in case the previous user was unreach able was out of radio coverage provided busy signal or did not answer the call This routine is continued until one of the preset users...

Page 22: ... s current state will be indicated on the keypads ATTENTION Bypassing a violated tamper is NOT allowed Please restore the tamper for example close sensor s enclosure before arming the system The built in EKB2 buzzer and ESIM364 buzzer if any provide short beeps continuously in case of alarm In addi tion the LCD screen back light level is boosted and the alarm message depending on violated zone typ...

Page 23: ...y out of 10 preset user phone numbers SMS text message content ssss_INFO ff tt Value ff frequency in days range 0 10 tt time range 0 23 Example 1111_INFO 2 15 every 2nd day at 15 00 1 In order to find out the system s current information send the following SMS text message to the system s phone number from any out of 10 preset user phone numbers SMS text message content ssss_INFO Example 1111_INFO...

Page 24: ...System status partition armed ON disarmed OFF Status of zones PGM outputs ON OFF Zone alarm texts PGM output names 3 In order to disable periodic SMS text message send the following SMS text message to the system s phone number from any out of 10 preset user phone numbers SMS text message content ssss_INFO 0 0 Example 1111_INFO 0 0 4 The system will reply with confirmation by SMS text message to t...

Page 25: ...mperature sensor name length 4 24 characters Example 1111_TEMP2 MIN 15 MAX 30 NAME Garage 3 In order to disable this SMS text message send the following SMS text message to the system s phone number from any out of 10 preset user phone numbers SMS text message content ssss_TEMPn MIN 0 MAX 0 Value n primary or secondary temperature sensor number range 1 8 Example 1111_TEMP1 MIN 0 MAX 0 4 In order t...

Page 26: ... battery voltage is 10 5V or lower BATTERY DEAD MISS Backup battery is not present or the battery voltage runs below 5V BATTERY FAILED Backup battery resistance is 2Ω or higher SIREN FAILED Siren is disconnected broken VIOLATED TAMPER One or more tampers are violated DATE TIME NOT SET Date time not set GSM CONNECT FAILED GSM connection is lost GSM ANTENNA FAILED GSM antenna is disconnected broken ...

Page 27: ...13 Z76 are violated 11 GSM antenna is disconnected broken 12 Wireless antenna is disconnected broken In order to find out which particular high numbered zone is violated please enter command B In order to find out which particular tamper is violated please enter command C A System fault indication enter command CODE B Violated high zone indication enter command CODE1 C Violated tamper indication e...

Page 28: ...xt message content ssss_Coo OFF or ssss_out name OFF Value oo PGM output number range 1 76 out name PGM output name Example 1111_C2 OFF 3 The system will reply with confirmation by SMS text message to the user phone number that sent the SMS text message 3 11 Controlling Electrical Appliances Your system features 4 or more PGM outputs intended for connection and control of various electrical applia...

Page 29: ...name Example 1111_C3 OFF 13 25 56 3 The system will reply with confirmation by SMS text message to the user phone number that sent the SMS text message SMS Fig No 35 User ESIM364 SMS SMS 3 12 Turning ON OFF the Electrical Appliances for a Determined Time Period NOTE PGM output can be turned ON for a determined time period only when it is in OFF state NOTE PGM output can be turned OFF for a determi...

Page 30: ...t message EKB2 EKB3 EKB3W keypad iButton key EWK1 wireless key fob Alarm indication by phone call Alarm indication by SMS text message Violated zone tamper name indication by SMS text message Temperature indication by SMS text message Periodical system information by SMS text message Main power loss restore indication by SMS text message Any other SMS text message generated by the system NOTE For ...

Page 31: ...MANUAL ELDES ESIM364 V1 2 31 ...

Page 32: ...Made in Lithuania www eldes lt iButton is a registered trademark of Maxim Integrated Products Inc ...

Reviews: