3.12.13 Display of the internal software version
Hold the
HOLD
key pressed and bring the rotary switch from the OFF position to the
A
position . The unit beeps,
the software version is displayed in the form UX.XX for 2 seconds, then all the segments of the display are shown
as long as the HOLD key is pressed.
3.12.14 Showing of display segments
See § 03.12.13. It is usually possible for any key-switch combination not described previously.
4. GENERAL SPECIFICATIONS
4.1 Dimensions and weight
70 x 193 x 37 mm 260 g
4.2 Clamp Tightening Capacity
<
26 mm
4.3 Power Supply
a standard 9 V alkaline battery (type CEI 6LF22, 6LR61 or NEDA 1604).To change it, see §7.1.
Average battery charge life: 60 h or 20,000 x 10 s measurements
6 Battery charge indicator
Flashing: charge life < 1 h Fixed: Change battery
Automatic OFF after 10 minutes with no action on the switch or the keys (reactivation by
switching from the OFF
4.4 Environmental parameters
Temperature - Humidity
Altitude
- Operation:
<
2.000 m
- Storage:
<
12000 m
Indoor use
Impermeability: protection index IP 40 (according to EN 60529, ed. 92)
4.5 Compliance with norms
Electrical safety:
secondo EN 61010-1, ed. 2001 e EN 61010-2-032, ed. 2003
- Dual insulation:
- Installation category: 600 V CAT III o 300 V CAT IV
- Pollution level: 2
Electromagnaetic compatibility
-
as
for EN 61326-1, ed. 2006
Mechanical resistance
- Free fall 1 m
(test as for IEC 68-2-32)
- Shock : 0,5 J
(test as foro IEC 68-2-27)
- Vibrazioni : 0,75 mm
(test as for IEC 68-2-6)
Auto- power OFF
(for UL94)
-
Housing: V0
- Jaws: V0
- Display window: V2
Temperature in °C
0
1
2
3
3
20
10
30
40
50
60
70
80
90
-50 -40
-30
-20
-10
0
10
20
30
40
50
60
70
80
90
Relative humidity in % HR
10