10.5 - DEVICE CODING

 

 

ELK22MP-A-B-C 

 

ELK22MPS-A-B-C 

 

ELK22MPM-A-B-C 

 

ELK22MPE-A-B-C 

 

 

A : SUPPLY 
24 

= 24 

 

(

VAC/VDC) 

240 

= 100... 240

 (VAC) 

 
B : OUTPUT OUT1

 

R

 = Relay 

 
C : OUTPUT OUT2

 

2R 

= Relay 

2S 

= Voltage output for SSR 

 

OUTPUT OUT3

 

For all models 
 

MODBUS COMMUNICATION

 

Only for ELK22MPM 
 

MODBUS TCP COMMUNICATION

 

Only for ELK22MPE 
 
 

10.6 – ACCESSORIES (Not supplied) 
 
ELK22DKP

 = Keyboard 

 

  
 
 
 

 
 
 

 

 
 
BC-8P

 = Connection cable for ELK22MP 

 

 
 
TC-8P 

= Connector for RS485 line terminal resistor. This connector 

has the termination resistor already integrated 

 
 
 

 

 

11 - PROBLEMS, MAINTENANCE AND WARRANTY

 

 
11.1 - ERROR REPORTING

 

Error

 

Reason

 

Action 

 

Fail 

Auto 

Autotuning 

not 

completed 

within 12 hours 

Check 

connection 

probe  and  actuator, 
then restart autotuning 

- - - -

 

Interruption of the probe 
 

Check that the probe is 
correctly  connected  to 
the  device,  and  then 
verify  that  the  probe  is 
working properly  
 

 
 
11.2 - CLEANING

 

It  is  recommended  to  clean  the  device  only  with  a  slightly  soaked 
cloth  of  water  or  non-abrasive  detergent  and  not  containing 
solvents. 

 
11.3 - WARRANTY AND REPAIR

 

The  device  is  guaranteed  by  manufacture  defects  or  defects  in 
material found within 12 months from the date of delivery.   
Warranty is limited to repair or replacement of the product.  
Possible  opening  of  the  container,  tampering  with  the  device,  or 
improper use and installation of the product will automatically result 
in the warranty being decayed.  
In  case  of  defective  product  during  warranty  period  or  out  of 
warranty period, contact the EL.CO. sales office. To get permission 
to ship.  
The defective product, therefore, accompanied by the indications of 
the  defect  found,  must  be  delivered  by  freight  forwarding  at  the 
EL.CO. factory, unless otherwise agreed. 
 
 
 

Summary of Contents for ELK22MP

Page 1: ...1 For normalized signals 4 20mA 0 10V It is designed for mounting on a din rail The ELK22MP series consists of 4 models 3 of these act as a centralizer and one of them as a slave The models of the ELK...

Page 2: ...he menu to select a module 5 4 red digits Process value during operation parameter selected during programming 6 4 green digits Setpoint value during operation value of the parameter selected during p...

Page 3: ...munication speeds adopted range from 1200 to 38400 baudrates and allow very satisfactory performances while remaining well below the limits imposed by the RS485 standard This allows the line to be wir...

Page 4: ...ters of the instrument can be read and written via serial communication The configurable parameters are found in Paragraph 6 4 WARNINGS FOR INSTALLATION AND USE 4 1 PERMITTED USE The device has been d...

Page 5: ...and a maximum of 1 to 31 slave devices A devices sequence that have ELK22MPM or ELK22MP as a centralizer must consist of a centralizer device and a maximum of 1 to 15 slave devices Two control units...

Page 6: ...must be the device to which the line is connected that must have the termination resistor To do this disconnect the resistance from the accessory and continue the line with the cables for RS485 as bel...

Page 7: ...programming the parameter Cont ON FN the parameter OxF H REG the parameter OyF C REG The adjustment operation operates on outputs depending on the measurement of the setpoint SP1 and hysteresis HPOS...

Page 8: ...nect one ELK22MP at time and set the ADR parameter before connect the next ELK22MP Example connect and power up the first ELK22MP program the ADR parameter to 0 and power off the system Connect the se...

Page 9: ...6 LHdo None 0x19 25 AL2 Alarm threshold SSP FSP 0 0x1A 26 HAL2 Hysteresis of alarm remedy 0 100 1 0x1B 27 AL2D Delay of alarm remedy 0 100 0 sec 0 0x1C 28 ADR Module address 1 16 16 0x1D 29 For each m...

Page 10: ...LSB byte 0 byte1 0x06 byte 2 byte 3 byte 4 byte 5 byte 6 byte 7 7 4 FUNCTION 7 READ ALLARM STATUS The request has the following frame Slave number Function number CRC LSB MSB byte 0 byte1 0x07 byte 6...

Page 11: ...the following frame Slave number Function number First word address MSB LSB Value to write MSB LSB byte 0 byte1 0x06 byte 2 byte 3 byte 4 byte 5 The normal reply is merely an echo of the request messa...

Page 12: ...ay outputs and front reinforced between low voltage parts 24 and 240 power supply and relay outputs and low voltage parts static inputs and outputs reinforced between power supply and relay outputs re...

Page 13: ...ption of the probe Check that the probe is correctly connected to the device and then verify that the probe is working properly 11 2 CLEANING It is recommended to clean the device only with a slightly...

Reviews: