![elco Combi 24 Operating Manual Download Page 44](http://html1.mh-extra.com/html/elco/combi-24/combi-24_operating-manual_2377072044.webp)
44
Parameters technician
Menu
Line no.
Selection possibilities
Unit
Min.
Max
Factory setting
Errors
6700
Message
-
0
65535
0
6705
SW diagnostic code
-
0
65535
0
6706
Burn ctrl phase lockout pos
-
0
255
0
6710
Reset alarm relay
-
0
1
0
6740
Flow temp 1 alarm
min
10
240
---
6741
Flow temp 2 alarm
min
---
6742
Flow temp 3 alarm
min
---
6743
Boiler temp alarm
min
---
6745
DHW charging alarm
h
1
48
---
6800
6810
6820
6990
Time stamp error
Note 1
Note 2
.....
Note 20
h:m
00:00
23:59
04
6803
6813
6823
6993
Error code
Note 1
Note 2
.....
Note 20
-
0
9999
0
6805
6815
6825
6995
SW diagnostic code
Past value 1
Past value 2
......
Past value 20
-
0
9999
0
6806
6816
6826
6996
Burner control phase
Past value 1
Past value 2
......
Past value20
-
0
255
0
Maintenance/Special
mode
7040
Burner hours interval
h
100
10000
1500
7041
Burn hrs since maintenance
h
0
10000
0
7042
Burner start interval
-
100
65500
9000
7043
Burn starts since maint
-
0
65535
0
7044
Maintenance interval
Months
1
240
24
7045
Time since maintenance
Months
0
240
0
7050
Fan speed ionization current
rpm
0
10000
0
7051
Message ionization current
-
No, Yes
No
7130
Chimney sweep function
-
Off, On
Off
7131
Burner output
-
Partial load, Full load, Max heating load
Full load
7140
Manual control
-
Off, On
Off
7143
Controller stop function
-
Off, On
Off
7145
Controller stop setpoint
%
0
100
50
7146
Deaeration function
-
Off, On
Off
7147
Type of venting
-
None, Heating circuit continuous,
Heating circuit cycled, DHW continuous,
DHW cycled
None
7170
Telephone customer service
-
0
9
0
7250
PStick storage pos
-
0
250
0
7251
PStick data description
-
0
255
0
7252
PStick command
-
No operation, Reading from stick,
Writing on stick
No operation
7253
PStick progress
%
0
100
0
7254
PStick status
-
0: No stick
1: No operation
2: Writing on stick
3: Reading from stick
4: EMC test active
5: Writing error
6: Reading error
7: Incompatible data set
8: Wrong stick type
9: Stick format error
10: Check data set
11: Data set disabled
12: Reading disabled
No Stick