23
0301 / 13 010 881C
EK01B.4 L-H
EK01B.4 L
EK01B.6 L
EK01B.9 L
Burner power
min./max. kW
18 - 42
20 - 42
30 - 55
45 - 95
Certification
According to EN 267 ; Emission class 2
Fuel oil flow rate
min./max. kg/h
1.52 - 3.54
1.69 - 3.54
2.53 - 4.64
3.8 - 8
Fuel oil
EL conforming to DIN 51603
Suction hose dimensions
mm
4 x 6
Airflow control I
Airflow control II
Linearised air metering drum, air shutoff flap
Turbulator in burner head
Control ratio
1 : 1
Voltage
230 V - 50 Hz
Electrical power consumption
W
244
195
195
233
Weight
ca. kg
10
Electric motor
2800 min.
-1
85-110 Watt
Protection index
IP 43
Control and safety unit
SH 1xx
Flame monitor
MZ 770 S
Ignition transformer
EBI-M 2 x 7.5 kV
Oil pump with electrovalve
AS 47 D
Nozzle line with preheating
FPHB5
-
-
-
Sound pressure level according to
VDI 2715 dB(A)
56
58
64
Burner performance calculation:
Q
F
= Burner power rating (kW)
Q
N
= Nominal boiler rating (kW)
η
K
= Boiler efficiency rating (%)
Q
N
Q
F
=
η
K
Working area
The working areas indicate burner
power relative to combustion chamber
pressure. They correspond to the
maximum values measured at the test
flame tube, in compliance with EN267.
The efficiency rating of the boiler
should be taken into account when
selecting a burner.
daPa
mbar
kW
42
20
0
2
4
6
8
10
15
25
35
45
55
0
0,2
0,4
0,6
0,8
1
daPa
mbar
kW
30
0
2
4
6
8
10
15
25
35
45
55
0
0,2
0,4
0,6
0,8
1
daPa
mbar
kW
42
18
0
2
4
6
8
10
15
25
35
45
55
0
0,2
0,4
0,6
0,8
1
EK01B.4 L-H
EK01B.4 L
EK01B.6 L
daPa
mbar
kW
45
95
0
2
4
6
8
10
12
40
50
60
70
80
90
100
0
0,2
0,4
0,6
0,8
1
1,2
EK01B.9 L
Explanation of type designation:
EK
= Manufacturer’s designation
01B
= Size
4/6/9
= Power index
L
= Light fuel oil
H
= Nozzle line heating
Summary
Technical data
Working area
EN
Summary of Contents for EK01B.4 L
Page 32: ...0301 13 010 881C 32...
Page 34: ...0301 13 010 881C 34...
Page 42: ...0301 13 010 881C 42 Notizen...
Page 43: ...43 0301 13 010 881C Notizen...