28
GAS SECTION
8
GAS INSTALLATION REQUIREMENTS
Important !
•
The walls adjacent to the cooker must be of heat-resistant material.
•
Before installation, make sure that the local distribution conditions (gas type and
pressure) and the adjustment of this appliance are compatible. The appliance
adjustment conditions are given on the plate or the label.
•
This appliance must be installed and serviced only by a suitably qualified,
registered installer. The installer shall refer to the local standards in force.
•
Failure to install the appliance correctly could invalidate any manufacturer’s
warranty.
This appliance is supplied for use on LPG (Cat.
I
3+, G30/G31, 28-30/37 mbar; check
the gas regulation label attached on the appliance).
CONNECTING THE APPLIANCE TO THE GAS SUPPLY
The gas connection must be carried out by an authorised person according to the relevant
standards.
Ensure that the room in which the cooker is to be installed is adequately ventilated, in
compliance with applicable regulations.
•
Connect the cooker to the gas mains utilizing rigid or flexible pipes.
•
The gas supply is connected at the rear of the cooker to the right or left terminal of the
gas inlet pipe (fig. 8.1a). The connection pipe must not cross the rear of the appliance.
•
The unused inlet pipe must be closed
off with the plug and sealing washer
supplied (fig. 8.1b).
Fig. 8.1b
Right or left
inlet pipe
Manifold male
pipe fitting
Sealing
washer (#)
Plug (#)
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
(#) Already fitted on the right or
left inlet pipe
Fitting the plug on the unused
terminal of the gas inlet pipe
Fig. 8.1a
plug
Summary of Contents for S 61 X 631 F