22
CORRECT REPLACEMENT OF THE
BURNERS
It is very important to check that the burner
flame distributor “
F
” and the cap “
C
” has
been correctly positioned (see figs. 6.2
- 6.3) failure to do so can cause serious
problems.
GAS TAPS
Periodic lubrication of the gas taps must be
carried out by specialist personnel only.
In the event of operating faults in the gas
taps, call the Service Department.
BURNERS AND PAN SUPPORTS
These parts can be removed and cleaned
with appropriate products.
After cleaning, the burners and their flame
spreaders must be well dried and correctly
replaced.
It is very important to check that the burner
flame spreader and the cap have been
correctly positioned. Failure to do so can
cause serious problems.
Check that the electrode “
S
” (fig. 6.2) next
to each burner is always clean to ensure
trouble-free sparking.
Note:
The electrode “S” must be very carefully
cleaned.
To avoid damage to the electric ignition
do not use it when the burners are not
in place.
S
F
C
Fig. 6.3
Fig. 6.2