46
ELECTRICAL SECTION
4
GENERAL
•
The connection to the electrical
network must be carried out by qualified
personnel and must be according to
existing norms.
•
The appliance must be connected to
the electrical network verifying above
all that the voltage corresponds to the
value indicated on the specifications
plate and that the cables section of the
electrical plant can bear the load which
is also indicated on the plate.
•
If the appliance is supplied without a
power supply plug and if you are not
connecting directly to the mains, a
standardized plug suitable for the load
must be fitted.
•
The colours of the wires in the appliance
power cable may not correspond with
the colours marked on the terminals of
your electrical plug. The plug should
always be wired as follows:
– connect the green/yellow wire to the
terminal marked with the letter “
E
”
or the earth symbol or coloured
green/yellow;
– connect the blue wire to the terminal
marked with the letter “
N
” or coloured
black;
– connect the brown wire to the
terminal marked with the letter “
L
” or
coloured red.
•
The bi-polar plug must be connected to
an outlet connected to the grounding
unit in conformity to security norms.
•
If the oven is to be connected directly
to the mains, it must be placed with
an omnipolar switch with minimum
opening between the contacts of 3 mm
between the appliance and the mains.
•
The power supply cable must not touch
the hot parts and must be positioned
so that it does not exceed 75°C at any
point.
•
Once the oven has been installed,
the switch or socket must always be
accessible.
•
If the power supply cable is damaged it
must be substituted by a suitable cable
available in the after sales service.
N.B. For connection to the mains, do
not use adapters, reducers or branching
devices as they can cause overheating
and burning.
If the installation requires alterations to the
domestic electrical system call an expert.
He should also check that the domestic
electrical system is suitable for the power
absorbed by the appliance.
Before effecting any intervention on
the electrical parts the appliance must
be disconnected from the network.
The connection of the appliance to the
grounding unit is mandatory.
The manufacturer declines every
responsability for any inconvenience
resulting from the inobservance of this
condition.