22
REPLACING THER POWER SUPPLY CABLE
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorized service agent in order to avoid a hazard.
Use the same type of power supply cable.
This cable must be connected to the terminal block following the diagram in fig. 3.1.
NOTE: The earth conductor must be left about 3 cm longer than the others.
SECTION OF THE SUPPLY CABLE
TYPE “H05V2V2-F”
resistant to temperatures of 90°C
220-240 V 50/60 hz
3 x 0,75 mm
2
(*) (**)
(*)
Connection possible with plug and outlet
(**)
Connection with wall box connection.
Fig. 3.1
L1
N(L
2
)
PE
220-240 V ac
E