TABLE FOR THE CHOICE OF THE INjECTORS
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30
28 mbar
Natural Gas
G20
20 mbar
Town Gas
G110
8 mbar
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Semi-rapid (SR)
1,75
0,45
66
101
192
Rapid (R)
3,00
0,75
87
129
280
Triple-ring (TR)
3,80
1,50
98
141
350
AIR VENT NECESSARY fOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Triple-ring (TR)
7,60
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fulfilled
with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
GAS MAINTENANCE
TESTING OPERATION
(FOR ALL GASES AND ALL TYPES OF CONNECTIONS)
The operation of the appliance MUST be tested before leaving.
Turn on the gas and light each burner. Check for a well-defined blue flame without any
yellow tipping. If any abnormailty is evident, check that the burner cap is located properly
and the injector nipple is aligned correctly.
Check the minimum burner setting by quickly rotating the burner knobs from the maximum
to the minimum position: the flame must not go out. If the adjustment is required, see
section “
SETTING ThE MINIMUM Of ThE COOKTOP BURNERS
” following.
If satisfactory performance cannot be obtained, check the installation and notify the local
gas supply authority of a gas supply problem, or if it is an appliance problem, Customer
Care should be called to obtain the nearest authorised Service Agent.