Elba DOMINO E35-200 XD Instructions For The Use - Installation Advices Download Page 15

15

When connecting the appliance to the gas supply with rigid pipes or a flexible hose, 

make sure that

• 

you use rigid pipes or a flexible hose complying with applicable local regulations. The 

flexible hose shall be of the correct construction for the type of gas being used and of 

the correct size to maintain the heat output of the appliance.

• 

the connection with rigid metal pipes does not cause stress or pressure to the gas 
piping.

• 

the flexible hose is not under tension, twisted, kinked or too tightly bent, neither while 

the appliance is in use nor while it is being connected or disconnected.

• 

the  flexible  hose  does  not  exceed  2000  mm  in  length  (or  refer  to  applicable  local 

regulations) and does not come into contact with sharp edges, corners or moving 

parts, as these may cause abrasion. Use a single flexible hose only; never connect the 

appliance with more than one flexible hose.

• 

the flexible hose can easily be inspected along its entire length to check its condition; 

if it has an expiry date, it should be replaced before that date.

• 

if using a flexible hose which is not entirely made of metal, make sure that it does not 

come into contact with any part of the cooktop with a surface temperature of 70°C or 
above (or refer to applicable local regulations).

• 

the flexible hose is not subject to excessive heat by direct exposure to flue products or 

by contact with hot surfaces.

• 

the rigid pipe or flexible hose is replaced if it shows signs of wear or damage.

• 

a gas pressure regulator, in compliance with the applicable local regulations, is 
installed when connecting to an LPG cylinder.

• 

the socket into which the plug of the flexible hose fit is permanently attached to a firmly 

fixed gas installation pipe and is positioned so that the hose hangs freely downwards.

• 

the plug of the flexible hose is accessible after installation, so that it can be disconnected 

for service or removal.

• 

you inform the customer that the cylinder valve or the supply valve immediately by the 
appliance should be closed when the cooktop is not in use.

• 

you inform the customer that the rigid pipe or flexible hose should not be subjected to 

corrosion by acidic cleaning agents.

After connecting the appliance to the gas supply, make sure that you

• 

check that the connections are correctly sealed using a soapy solution, but never a 

naked flame.

• 

check whether the injectors are correct for the type of gas being used. If not, follow the 

instructions under “GAS MAINTENANCE”.

• 

replace the sealing washer/s on the slightest sign of deformation or imperfection. The 
sealing washer/s is/are the part/s which guarantee/s a good seal in the gas connection.

GAS CONNECTION FOR TOWN GAS ONLY

The gas connection is made up of (Fig. 2.3):

• 

the appliance inlet pipe;

• 

the foating nut;

• 

the brass elbow;

• 

the brass conical connector [1/2” BSP taper (conical), BS EN 10226-1, male thread];

• 

sealing washers;

• 

the Town gas pressure regulator.

Summary of Contents for DOMINO E35-200 XD

Page 1: ...Instructions for the use Installation advices 100 ELBAQUALITY MADE IN ITALY Made in Italy DOMINO COOKING HOBS EHS 311D1 S EHS 321D1 S...

Page 2: ...lease preserve this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for th...

Page 3: ...ed by the norms The complete safety of the appliance also depends on the correct use we therefore recommend to always pay a extreme attention while using the product especially in the presence of chil...

Page 4: ...in relation to children who could play with unused appliances The various components of the appliance are recyclable Dispose of them in accordance with the regulations in force in your country If the...

Page 5: ...d your product meets all safety requirements laid down for this type of product category However special care should be taken around the underneath of the appliance as this area is not designed or int...

Page 6: ...6 ADVICE for the INSTALLER...

Page 7: ...personal injury or damage This appliance shall only be serviced by authorized personnel Always disconnect the appliance from mains power supply before carrying out any maintenance operations or repair...

Page 8: ...ed above an oven the two appliances shall be connected to the gas and or electrical supply with independent connections The cooker top must be kept no less than 100 mm away from any side wall from sid...

Page 9: ...careful to overlay the junction edges fig 1 2b Turn the cooktop over and put tabs A fig 1 2a into the mountings only tighten screws B a few turns Make sure that the tabs are mounted correctly as shown...

Page 10: ...t they cannot be blocked from either the inside or the outside When these openings cannot be made the necessary air can come from an adjacent room which is ventilated as required as long as it is not...

Page 11: ...ied for use on Town gas they are adjusted for this gas only and cannot be used on any other gas Natural gas or LPG without modification The appliances are manufactured for conversion to Natural gas an...

Page 12: ...URAL GAS or TOWN GAS Hose clamp not supplied Rubber hose not supplied for NATURAL GAS connection internal diameter 13 mm Rubber hose not supplied for LPG connection internal diameter 8 mm Hose clamp n...

Page 13: ...hose must comply with the applicable local regulations and be of the correct construction for the type of gas being used 3 Make sure that the hose is tightly and securely fitted at both ends 4 Use a s...

Page 14: ...ons under GAS MAINTENANCE replace the sealing washer s on the slightest sign of deformation or imperfection The sealing washer s is are the part s which guarantee s a good seal in the gas connection G...

Page 15: ...products or by contact with hot surfaces the rigid pipe or flexible hose is replaced if it shows signs of wear or damage a gas pressure regulator in compliance with the applicable local regulations i...

Page 16: ...pressure to which it will be connected the flexible hose shall not be more than one meter in length for domestic appliance connection Use a single flexible hose only never connect the cooktop with mo...

Page 17: ...emale 1 2 BSP female Supplied with the appliance in a separate kit Appliance inlet pipe Floating nut Brass elbow Sealing washer Sealing washer Brass conical connector Gas pressure regulator for Town g...

Page 18: ...ility resulting from the non compliance of this obligation GAS MAINTENANCE TESTINGOPERATION FORALLGASESANDALLTYPESOFCONNECTIONS The operation of the appliance MUST be tested before leaving Turn on the...

Page 19: ...he injectors the gas regulation label at the bottom of the appliance shall be replaced by the new label supplied together with the injectors gas conversion kit The burners are conceived in such a way...

Page 20: ...ing the gas test gauge U gauge Connect the U gauge to the test point with tube hose refer to Fig 2 7 Turn on the gas burner the biggest burner to the maximum power and adjust the pressure to 8 mbar by...

Page 21: ...ith the letter E or the earth symbol or coloured green yellow connect the blue wire to the terminal marked with the letter N or coloured black connect the brown wire to the terminal marked with the le...

Page 22: ...r supply cable This cable must be connected to the terminal block following the diagram in fig 3 1 NOTE The earth conductor must be left about 3 cm longer than the others SECTION OF THE SUPPLY CABLE T...

Page 23: ...23 ADVICE for the USERS...

Page 24: ...rner control knob 2 5 Semirapid burner control knob 1 6 Triple ring burner control knob 3 NOTE The electric ignition is incorporated in the knobs The model has a safety valve system fitted the flow of...

Page 25: ...between the maximum aperture and closed positions Fig 2 1 GAS BURNERS 2 Caution Do not cover the hob with aluminium foils N B When the cooktop is not being used set the gas knobs to their closed posi...

Page 26: ...CHOICE OF THE BURNER On the control panel near every knob there is a diagram that indicates which burner is controlled by that knob The suitable burner must be chosen according to the diameter and the...

Page 27: ...with the appliance it is available as an accessory at extra cost in order to avoid any faulty operation of the triple ring burner figs 2 4a 2 4b 2 5a 2 5b The flat bottomed pans are to be placed dire...

Page 28: ...our product meets all safety requirements laid down for this type of product category However special care should be taken around the underneath of the appliance as this area is not designed or intend...

Page 29: ...he burners are not in place CORRECT REPLACEMENT OF THE SEMIRAPID AND RAPID BURNERS It is very important to check that the burner flame spreader F and the cap C have been correctly positioned see figs...

Page 30: ...30 Fig 3 1 Fig 3 2 Fig 3 3 Fig 3 4 Fig 3 5 S F C T A B S T...

Page 31: ...31...

Page 32: ...ng or transcription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacturer commercial reasons at any moment and w...