![Elation PROTHEUS HYBRID User Manual Download Page 40](http://html.mh-extra.com/html/elation/protheus-hybrid/protheus-hybrid_user-manual_2376296040.webp)
40
E R R O R C O D E S
Error Codes are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
Animation Wheel Er
The Animation Wheel movement is not located in the default position after the
reset. This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or a defective motor IC drive on the main PCB). This error may
also be displayed if the head/yoke was blocked during a reset function.
Dimmer Er
The Dimmer movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a motor failure
(defective motor or defective motor IC drive on main PCB). This error may also be
displayed if the head was blocked during a reset function.
Frost
Wheel Er
The Frost Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
Fan Moving
Wheel Er
The Fan Moving Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
Array Lens
Wheel Er
The Array Lens Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
1U_FanJB1Fault
Error information from JB1 port on 1U01 PCB.
1U_FanJB2Fault
Error information from JB2 port on 1U01 PCB.
3U_FanJB1Fault
Error information from JB1 port on 3U PCB.
3U_FanJB2Fault
Error information from JB2 port on 3U PCB.
4U_FanJB2Fault
Error information from JB2 port on 4U PCB.
5U_FanJB1Fault
Error information from JB1 port on 5U PCB.
6U_FanJB1Fault
Error information from JB1 port on 6U PCB.
7U_FanJB1Fault
Error information from JB1 port on 7U PCB.
7U_FanJB2Fault
Error information from JB2 port on 7U PCB.
7U_FanJB3Fault
Error information from JB3 port on 7U PCB.