![Elation PROTHEUS HYBRID User Manual Download Page 39](http://html.mh-extra.com/html/elation/protheus-hybrid/protheus-hybrid_user-manual_2376296039.webp)
39
E R R O R C O D E S
Specifications and features are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
Rotating Gobo
Rotation Er
The Rotating Gobo rotation movement is not located in the default position after
the reset. This message will appear after a fixture reset if the gobo wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive on
main PCB).
Fixed Gobo
Wheel Er
The Fixed Gobo Wheel movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel’s magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
Prism Wheel 1 Er
The Prism Wheel 1movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel’s magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
Prism Rotation
Wheel 1 Er
The Prism Wheel 1 rotation movement is not located in the default position after
the reset. This message will appear after a fixture reset if the gobo wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive on
main PCB).
Prism Wheel 2 Er
The Prism Wheel 2 movement is not located in the default position after the reset.
This message will appear after a fixture reset if the gobo wheel’s magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
Prism Rotation
Wheel 2 Er
The Prism Wheel 2 rotation movement is not located in the default position after
the reset. This message will appear after a fixture reset if the gobo wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or
there is a stepper motor failure (defective motor or defective motor IC drive on
main PCB).
Focus Er
The Focus movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-
indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or defective motor IC drive on main PCB).
Zoom Er
The Zoom movement is not located in the default position after the reset. This
message will appear after a fixture reset if the gobo wheel’s magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper
motor failure (defective motor or defective motor IC drive on main PCB).